My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-21935
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21935
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2021 11:25:25 AM
Creation date
3/24/2021 11:25:22 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
19-21935
Building Department - Name
HILTON JR,BOBBY E
Address
5885 13TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Manual S Compliance Report Jab: R0818410 <br /> wrightsoft Date: 0811012018 <br /> Entire House By. MKC <br /> Bobby Hilton Construction,Inc Plan: 611600 <br /> 399420fisAJ[en Rd,ZaptWNIKFL3354OPhore:(813)997-0515 <br /> Project Information <br /> For Bobby Hilton Construction,Inc. <br /> Zephyrhills,FL 33540 <br /> Cooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 91AOF Sensible gain: 17415 Btuh Entering coil DB: 77.3°F <br /> Outdoor design W& 7721F Latent gain: 3659 Btuh Entering coil WB: 63.8°F <br /> Indoor design DB. 75.0°F Total gain: 21074 Btuh <br /> Indoor RH: 50% Estimated airflow: 800 clrn <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipmentlype: SplitASHP <br /> Manufacturer. Franklin or Eqv. Model: GSZ160241+ASPT29B14 <br /> Actual airflow. 800 cfrn <br /> Sensible capacity. 18000 Btuh 103%of load <br /> Latent capacity- 6000 Btuh 164%of load <br /> Total capacity: 24000 Btuh 114%of load SHR, 75% <br /> Heating Equipment <br /> Design Conditions <br /> Outdoor design DB: 42.9°F Heat loss: 15763 Btuh Entering coil DR 69.1°F <br /> Indoor design DB- 70.0°F <br /> Manufacturer's Perfonnance Data at Actual Design Conditions <br /> Equipment type: SplitASHP <br /> Manufacturer. Franklin or Eqv. Model: GSZ160241+ASFrT29BI4 <br /> Actual airflow. 800 cfirn <br /> Output capacity." 24000 Btuh 152%of load Capacity balance: 33 OF <br /> Supplemental heat required: 0 Btuh Economic balance: -99 OF <br /> Backup equipment type: Bec strip <br /> Manufacturer. Model: <br /> Actual airflow. 800 cIrn <br /> Output capacity. 5.0 kW 108%of load Temp.rise: 31 OF <br /> Meets all requirements ofACCA Manual S. <br /> wrightsoft- 201&kg-1411.4558 <br /> PJgtt-SUteDUrivefsal20l8i8D.19RSU2DT73 <br /> Page 1 <br /> 818410-BobbyHltDnODrsVucdonMB184I0np Calc=W8 FrortDoorfacm E <br />
The URL can be used to link to this page
Your browser does not support the video tag.