Laserfiche WebLink
x <br /> Specifications <br /> VS1 VS4 <br /> Device loops 1 loop Class B or Class A(Styles 4,6,7)supporting up to 1 loop,expandable to 4,Class A or B(Styles 4,6,7), <br /> 64 device addresses(any combination of detectors and each loop supporting up to 250 device addresses(125 <br /> modules) detectors and 125 modules max.).Addresses 1 to 125 are <br /> Maximum T-taps:63 for detectors and addresses 126 to 250 are for modules <br /> (each device can be on its own branch) Maximum T-taps/loop:124 <br /> Notification appliance 2 Class B(Style Y),Class A(Style Z)optional 4 Class B(Style Y)or 2 Class A(Style Z) <br /> circuits 3.75 A FWR total at 120/230 VAC 60 Hz 6.0 A FWR total at 120/230 VAC 60 Hz <br /> 3.0 A FWR total at 230 VAC 50 Hz 5.0 A FWR total at 230 VAC 50 Hz <br /> 2.5 A FWR each max.per circuit 2.5 A FWR each max.per circuit <br /> Primary power 120 VAC,60 Hz,1.3 A max. 120 VAC,60 Hz,2.0 A max. <br /> 230 VAC,50-60 Hz,0.62 A max. 230 VAC,50-60 Hz,0.97 A max. <br /> Base panel current standby 155 mA 172 mA <br /> Base panel current alarm 204 mA 267 mA <br /> Input zones 16 max. 32 max. <br /> Remote annunciator 8 drops max.,RS-485 Class B,Class A is optional 8 drops max.,RS-485 Class A or B <br /> Data line length:4,000 ft.(1,219 m) Data line length:4,000 ft.(1,219 m) <br /> Operating voltage 24 VDC panel <br /> Auxiliary power output Aux power 1:500 mA,24 VDC <br /> circuit Aux power 2:500 mA,24 VDC(1 A possible if you reduce total available NAC power by 500 mA) <br /> Output:28.3 to 21.9 VDC,special application <br /> Note:For a list of compatible devices,see the VS1 and VS4 Series Compatibility List(P/N 3102354-EN) <br /> Loop circuit Maximum loop resistance:66 D <br /> Maximum loop capacitance:0.5 pF <br /> Communication line voltage:Maximum 20.6 V peak-to-peak <br /> Operating current(fully loaded loop)Stand by:55 mA/45 mA <br /> Alarm: 125 mA/115 mA(not including two-wire smoke modules) <br /> Circuit current:0.5 A max.Style 4,6,and 7 wiring <br /> Max.resistance between isolators:Limited only by overall wire run lengths <br /> 64 isolators maximum per loop(total both isolator bases and modules) <br /> Batteries Type:Sealed lead acid _ <br /> Voltage:24 VDC <br /> Charging current:2.47 A max.Amp hour capacity:26 Ah <br /> Standby operation:24 hour or 60 hour <br /> Placement:Up to two 10 Ah batteries will fit in the VS1 control panel cabinet and two 18 Ah batteries will fit in the VS4 <br /> control panel cabinet.If larger batteries are required,use a battery cabinet. <br /> SA-DACT dialer Phone line type:One or two loop-start lines on a public,switched network <br /> Phone line connector:RJ-31/38X(C31/38)) <br /> Communication formats:Contact ID(SIA DC-05) <br /> Operating current Standby/Alarm:41 mA Max.:100 mA <br /> FCC registration number:GESAL01 BSADACT <br /> Industry Canada Registration number:3944A-SADACT <br /> Ringer equivalence number:0.1 B <br /> Ground fault impedance 0 to 5 kQ <br /> Alarm contact Form C N.O.24 VDC at 1 A(resistive load) <br /> Trouble contact Form C 24 VDC at 1 A(resistive load) <br /> Supervisory contact Form A N.O.24 VDC at 1 A(resistive load) <br /> Environmental Temperature:0 to 49°C(32 to 120T)Relative humidity:0 to 93%noncondensing <br /> Terminal rating All terminals rated for 12 to 18 AWG(0.75 to 2.5 mm2) <br /> Page 7 of 8 0 A T A. s H t_t_ T V85005-0135 <br /> Not lo I_-a,:.*:. ,.;r r.;, ;la::,tii,; .EtrF<,s ., Issue 1.3 <br />