9 <br /> Application Dimensions <br /> The MIRBPS provides additional power and circuits for notification <br /> appliances and other 24 Vdc loads. It is listed for indoor dry loca- <br /> tions and can easily be installed where needed. O Top View O <br /> Fault conditions are indicated on the on-board diagnostic LEDs, <br /> opening the MIRBPS input sense circuit and the trouble relay(if If-D2 D3 <br /> programmed).While this provides indication to the host system, <br /> the MIRBPS can still be activated upon command.A separate AC Of—D4�0 <br /> Fail contact is available on the MIRBPS circuit board,which can <br /> be programmed for trouble or AC Fail.There are seven on-board o <br /> diagnostic LEDs:one for each NAC fault, one for battery fault,one a: Front View 0 <br /> for ground fault,and one for AC power. <br /> m <br /> The unique dual-input activation circuits of the MIRBPS can be <br /> activated by any voltage from 6 to 45 VDC(filtered-regulated)or to 0 <br /> 11 to 33 Vdc(full-wave rectified, unfiltered).The first input circuit D1 D6 <br /> can be configured to activate 1-4 of the four possible outputs.The 0 <br /> second input circuit can be configured to control circuits 3 and 4. All knockouts m <br /> When outputs are configured for auxiliary operation,these circuits for 3/4 in conduit < <br /> can be configured to stay on or automatically deactivate 30 sec- . (1.9 cm) CD <br /> onds after AC power is lost.This feature makes these circuits ideal <br /> for door holder applications.The MIRBPS also has a separate 200 <br /> mA 24 Vdc output that can be used to power internal activation <br /> modules. <br /> MIRBPS NACs can be configured for a 3-3-3 temporal or continu- D1 D2 D3 D4 D5 D6 <br /> ous output.California temporal rate outputs are also available on 17.0 in 3.5 in 13.0 in 6.5 in 3.375 in 12.0 in <br /> certain models.This makes the MIRBPS ideal for applications re- (43.2 cm) (8.9 cm) (33.0 cm) (16.5 cm) (8.6 cm) (30.4 cm) <br /> quiring signaling rates that are not available from the main system. <br /> In addition to the internally generated signal rates,the MIRBPS <br /> can also be configured to follow the coded signal rate of the main Wire routing Power-limited <br /> system NACs.This allows for the seamless expansion of existing wiring area <br /> NACs. <br /> The MIRBPS enclosure has mounting brackets for up to three . <br /> Signature modules to the right of the circuit board. np <br /> o° <br /> Engineering Specification Supply,where needed, Kidde MIRBPS Series Booster Power Sup-plies(MIRBPS)that are interconnected to and supervised by themain system.The MIRBPS shall function as a stand-alone auxiliary <br /> power supply with its own fully-supervised battery compliment. g ]r'F2'� <br /> The MIRBPS battery compliment shall be sized to match the RouteACsupply <br /> requirements of the main system.The MIRBPS shall be capable through these <br /> of supervising and charging batteries having the capacity of 24 knockouts only _ <br /> ampere-hours for Mass Notification/Emergency Communication (Nonpower-limited <br /> (MNEC), life safety and security applications,and the capacity of and supervised) Battery wiring (nonpower- <br /> 65 ampere-hours for access control applications. o limited and supervised) o <br /> <<The MIRBPS shall be capable of installation for a seismic com- Battery Battery <br /> ponent Importance Factor of 1.5.>>The MIRBPS shall provide <br /> a minimum of four independent,fully supervised Class B circuits <br /> that can be field configurable for notification appliance circuits or <br /> auxiliary 24 Vdc power circuits. MIRBPS NACs shall be convertible <br /> to a minimum of two Class A NACs. Each MIRBPS output circuit Notes <br /> shall be rated at 3 amperes at 24 Vdc. Each output circuit shall 1• Maintain 1/4-inch(6 mm)spacing between power-limited and nonpower-limited <br /> be provided with automatically restoring overcurrent protection. wiring or use type FPL,FPLR,or FPLP cable per NEC. <br /> The MIRBPS shall be operable from the main system NAC and/or [2] Power-limited and supervised when not configured as auxiliary power.Non- <br /> The Y supervised when configured as auxiliary power. <br /> Kidde Signature Series control modules. MIRBPS NACs shall be [3] Source must be power-limited.Source determines supervision. <br /> configurable for continuous,3-3-3 temporal or optionally, Califor- 4. When using larger batteries,make sure to position the battery terminals towards <br /> nia rate. Fault conditions on the MIRBPS shall not impede opera- the door. <br /> tion of main system NAC.The MIRBPS shall be provided with <br /> ground fault detection circuitry and a separate AC fail relay. <br /> Page 2 of 4 n A.i.A s H E E T K85005-0125 <br /> IY r,t to bu uopci tpr msi.a'i,ttinn Issue f <br />