i <br /> Specifications <br /> a9 f �'� Model _ 6.5 amp Booster _ 10 amp Booster <br /> AC Line Voltage 120VAC or 220-240VAC 50/6OHz 120VAC or 220-240VAC 50/6OHz <br /> 390 watts 580 watts <br /> Technology that saves lives Notification Appliance 3.OA max.per circuit @ 24Vdc 3.OA max.per circuit @ 24Vdc <br /> Circuit Ratings nominal 6.5A max total all NACs nominal 1 OA max total all NACs <br /> Contact us... Trouble Relay 2 Amps @ 30Vdc <br /> Email:kidde.fire@fs,utc.com Auxiliary Outputs Four configurable outputs replace NACs 1,2,3 or 4. as auxiliary <br /> Web: Kidde.com/EnoineeredSystems outputs and 200 mA dedicated auxiliary.(See note 2.) <br /> Input Current 3mA @ 12Vdc,6mA @ 24Vdc <br /> (from an existing NAC) _ <br /> Kidde is a UTC brand. <br /> 1016 Corporate Park Drive Booster Internal 70mA+35 mA for each circuit set to AUX <br /> Mebane,NC 27302 Supervisory Current <br /> Booster Internal Alarm ' 270mA <br /> ©2016 United Technologies Corporation. Current <br /> All rights reserved. Signature Mounting <br /> Space Accomodates three two-gang modules. <br /> 10 Amp Hours(2 of 12V1 OA)in cabinet up to 24 Amp hours with ex- <br /> Maximum Battery Size ternal battery cabinet for fire and security applications;up to 65 Amp <br /> hours for access control applications in external battery box. _ <br /> Terminal Wire Gauge 18-12 AWG <br /> Relative Humidity 0 to 93%non condensing @ 32°C <br /> Temperature Rating 32'to 120°F(0'to 49°C) <br /> NAC Wiring Styles Class A or Class B <br /> Output Signal Rates Continuous,California rate,3-3-3 temporal, <br /> or follow installed panel's NAC.(See note 1.) <br /> Ground Fault Detection _ Enable or Disable via jumper_ _ <br /> Agency Listings v UL,ULC,CSFM <br /> 1. Model MIRBPS'CAA provides selection for California rate,in place of temporal. <br /> 2. Maximum of 8 Amps can be used for auxiliary output. <br /> Ordering Information <br /> Catalog Number Description Shipping Wt. <br /> lb(kg) <br /> MIRBPS6A 6.5 Amp Booster Power Supply 13(5.9) <br /> MIRBPS6AC 6.5 Amp Booster Power Supply(ULC) 13(5.9) <br /> MIRBP_S6A/230 6.5 Amp Booster Power Supply(220V) _ 13(5.9) <br /> MIRBPS6CAA 6.5 Amp Booster Power Supply with California rate 13(5.9) <br /> MIRBPSI OA 10 Amp Booster Power Supply 13(5.9) _ <br /> MIRBPSI0AC 10 Amp Booster Power Supply(ULC) 13(5.9) <br /> MIRBPSI0A/230 10 Amp Booster Power Supply(220V) 13(5.9) <br /> MIRBPSI0CAA 10 Amp Booster Power Supply with California rate 13(5.9) <br /> Related Equipment <br /> 12V6A5 7.2 Amp Hour Battery,two required 3.4(1.6) <br /> 12V1 OA 10 Amp Hour Battery,two required 9.5(4.3) <br /> 3-TAMP Tamper switch <br /> Notes: BC-1 Battery Cabinet(up to 2-40 Amp Hour Batteries) 58(26.4) <br /> 1. Requires installation of separate battery BC-2 Battery Cabinet(up to 2-17 Amp Hour Batteries) 19(8.6) <br /> cabinet. BC-1 EQ Seismic hardening Kit for BC-1 cabinets.Includes battery hard- <br /> 2. MIRBPS supports batteries greater than ening order BC-1 enclosure separately._ <br /> 24 Amp hours for access control applica- <br /> tions BPSEQ Seismic kit for MIRBPS6A or MIRBPSI O Booster Power Su <br /> only. p- <br /> 3. For earthquake anchorage,including plies.See note 3. <br /> detailed mounting weights and center of 12V17A 18 Amp Hour Battery,two required(see note 1) 13(5.9) <br /> gravity detail,please refer to Seismic Ap- 12V24A 24 Amp Hour Battery,two required(see note 1) 20(9.07) <br /> plication Guide 3101 g87-EN.Approval of 12V40A 40 Amp Hour Battery,two required(see notes 1,2) 32(14.5) <br /> panel anchorage to site structure may re- 12V50A 50 Am Hour Batte two required see notes 1,2 40 <br /> quire local AHJ,structural,or civil engineer P ry, q ( ) (18.14) <br /> review. 12V65A 65 Amp Hour Battery,two required(see notes 1,2) 49(22.2) <br /> 4 <br /> Page 4 of 4 D A 1 A SHEET K85005-0125 <br /> €poi t+; bo usr.ti for in,taa;t?L,n {;ur>os„,. Issue 1 <br />