My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-22223
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-22223
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/25/2021 10:27:28 AM
Creation date
3/25/2021 10:27:23 AM
Metadata
Fields
Template:
Building Department
Company Name
FRATERNAL ORDER OF EAGLE
Building Department - Doc Type
Permit
Permit #
20-22223
Building Department - Name
FRATERNAL ORDER OF EAGLE
Address
38421 5TH AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
c <br /> Application Installation <br /> The duty performed by the GSA-MM1 and GSA-WTM is de- The GSA-MM1 and GSA-WTM modules mount to North American <br /> termined by their factory assigned sub-type code or"Personality 2-1/2 inch(64 mm)deep one-gang boxes and 1-1/2 inch(38 mm) <br /> Code". deep 4 inch square boxes with one-gang covers and GSA-MP <br /> GSA-WTM NORMALLY-OPEN ALARM -DELAYED LATCH- mounting plates.The terminals are suited for#12 to#18 AWG <br /> ING(Factory set Personality Code 2)-Assigned to one circuit. (2.5 mm2 to 0.75 mm2)wire size. <br /> Configures circuit 1 for Class B normally-open Waterflow Alarm Kidde recommends that this module be installed according to lat- <br /> Switches.An ALARM signal is sent to the loop controller when est recognized edition of national and local fire alarm codes. <br /> the input contact is closed for approximately 16 seconds.The Electronic Addressing-The loop controller electronically <br /> alarm condition is latched at the module. <br /> addresses each module,saving valuable time during system <br /> GSA-WTM NORMALLY-OPEN ACTIVE-LATCHING(Factory commissioning. Setting complicated switches or dials is not <br /> set Personality Code 4)-Assigned to one circuit. Configures required. Each module has its own unique serial number stored <br /> circuit 2 for Class B normally open dry contact Supervisory and in its on-board memory,The loop controller identifies each device <br /> Tamper Switches.An ACTIVE signal is sent to the loop controller on the loop and assigns a"soft"address to each serial number. <br /> when the input contact is closed.The active condition is latched at If desired,the modules can be addressed using the SIGA-PRO <br /> the module. Signature Program/Service Tool. <br /> GSA-MM1 NORMALLY-OPEN ACTIVE-NON-LATCHING Personality codes are assigned by the factory. No user configura- <br /> (Factory set Personality Code 3)-Assigned to one circuit. tion is required for these modules. <br /> Configures circuit 1 for Class B normally-open dry contact <br /> monitoring input such as from Fans, Dampers, Doors,etc.An <br /> ACTIVE signal is sent to the loop controller when the input contact Compatible electrical box <br /> is closed.The active condition is not latched at the module.Com- <br /> patibility <br /> The Signature Series modules are compatible only with Kidde's <br /> Signature Loop Controller. <br /> Wall plate,white <br /> Warnings & Cautions (1-gang) <br /> This module will not operate without electrical power.As fires fre- <br /> quently cause power interruption,we suggest you discuss further a <br /> safeguards with your local fire protection specialist. o <br /> d• <br /> mm <br /> Q• <br /> Compatibility <br /> These modules are part of Kidde's Signature Series intelligent pro- <br /> cessing and control platform.They are compatible with VM, and Q <br /> VS Series control panels. <br /> Q <br /> Testing & Maintenance <br /> The module's automatic self-diagnosis identifies when it is defec- <br /> tive and causes a trouble message.The user-friendly maintenance <br /> program shows the current state of each module and other perti- <br /> nent messages.Single modules may be turned off(de-activated) <br /> temporarily,from the control panel.Scheduled maintenance(Reg- <br /> ular or Selected)for proper system operation should be planned to <br /> meet the requirements of the Authority Having Jurisdiction(AHJ). <br /> Refer to current NFPA 72 and ULC CAN/ULC 536 standards. <br /> Availability of maintenance features is dependent on the fire alarm <br /> system used. <br /> Page 2 of 4 DATA sH E F T K85001-0297 <br /> Not to bn usoct te; Issue 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.