My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-22223
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-22223
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/25/2021 10:27:28 AM
Creation date
3/25/2021 10:27:23 AM
Metadata
Fields
Template:
Building Department
Company Name
FRATERNAL ORDER OF EAGLE
Building Department - Doc Type
Permit
Permit #
20-22223
Building Department - Name
FRATERNAL ORDER OF EAGLE
Address
38421 5TH AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Typical Wiring <br /> The module will accept#18 AWG(0.75mm2), #16(1,OMM2). #14 AWG(1.50mm2),#12 AWG(2.50mm2) wire sizes. <br /> Note: Sizes#16 AWG(1.0mm2)and#18 AWG(0.75mm2)are preferred for ease of installation. See Signature Loop Controller catalog <br /> sheet for detailed wiring requirement specifications. <br /> Initiating(Slave)Device Circuit Wire Specifications <br /> Maximum Allowable Wire Resistance 50 ohms(25 ohms per wire)per Circuit <br /> Maximum Allowable Wire Capacitance 0.1 uF per Circuit _ <br /> - —For Design Reference: Wire Size -` Maximum Distance to EOLR <br /> _ #18 AWG(0.75 mm2) _ <br /> #16 AWG(1.00 mm2) 4,000 ft(1219 m) <br /> _ #14 AWG(1.50 mm2) <br /> T #12 AWG(1.50 mm2) <br /> Typical N.O.Wlaterflow Contact Typical Supervisory Contact Typical N.O.Monitor Contact <br /> 1 INPUT 1 INPUT 2 <br /> 1 <br /> Ql Q2 Q4 Style B(Class B) 1 <br /> 1 1 T82 <br /> TB2 <br /> 8 7 UL/ULC Listed <br /> UL/ULC Usted Style B(Class B) 8 7 5 5 0 0 0 47KQ EOL <br /> 0 0 o UL/ULC Listed <br /> 47KQ EOL pl Q2 A47KQ EOL <br /> Red LED Green LED <br /> Red LED ® ® Green LED (Alarm/Active) ® ® (Normal) <br /> (Alarm/Active) 4 3 2 t (Normal) 4 3 2 1 <br /> TB1 <br /> TBl <br /> {(DATA IN(+) DATA OUT(+)l} j( DATA IN(+) DATA OUT(+) <br /> `DATA IN(-) DATA OUT(-)1 ` DATA IN jo DATA OUT(-) <br /> From Signature Controller To Next Device From Signature Controller To Next Device <br /> or Previous Device Q or Previous Device Q <br /> Model GSA-WTM Model GSA-MM9 <br /> Notes <br /> Al Maximum 25 ohms resistance per wire. <br /> A Maximum#12 AWG(2.5mm2)wire. Min. #18(0.75mm2) <br /> ARefer to Signature Loop Controller Installation Sheet for <br /> wiring specifications. <br /> A Maximum 10 Vdc Q 350pA. <br /> 5) All wiring power limited and supervised. <br /> 6) This module will NOT support 2-wire smoke detectors. <br /> Page 3 of 4 CA I A 3;r E L; r- K85001-0297 <br /> Not tO bO. uSC:J for in St AUl 4!ion pur;,oL;R.S. Issue 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.