Laserfiche WebLink
1 <br /> D <br /> 4 <br /> t <br /> Single Family D elling <br /> Plan Review Comments <br /> 1. F.F.E: shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to comply with R401.3 of the F.B.C. <br /> I Compaction test required if 24"or more of fill dirt is brought in at any one place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5; Driveways require a R.O.W. use permit: All 4 sides f driveway thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> 7. All property markers shall be uncovered and marked at time of first inspection. <br /> 8: All A.D.A. requirements shall be met. <br /> 9. No electric,plumbing,mechanical, or framing shall a:covered without an inspection and <br /> approval first. <br /> 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). <br /> 1.1. Appliances shall not be installed_ in a location where subject to mechanical damage unless <br /> protected by approved barriers. M303 A of the F.B. <br /> 12. Water heaters shall comply with section P607.3 oft e R.B.C. <br /> 13. Foundation supports for A/C units shall be raised at east 3" above finished grade. M1308.1 <br /> 14. Return air in all bedrooms. F.B.C. M1620.4 <br /> 15. Smoke detectors are to be installed in accordance w. h R313.1 of the F.B.C. <br /> 16:All glazing requirements are to be in accordance wit R308.4 of the F.B.C. <br /> 17. All means of egress are to be in accordance with R3 I of the F.B.C. <br /> 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. <br /> 10. Combination-type AFCI breakers are required at all ocations requiring an AFCI.type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be ilistalled in accordance with the F.B.C: <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit to unit. This includes all <br /> underground.plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced. <br />