Laserfiche WebLink
J <br /> 23. Tamper-Resistant.Receptacles in accordance with 40 .11 of the 2016 N.E.0 <br /> 24. In accordance with the Land Development Code, lots,shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25. R403.5.3Hot water pipe insulation <br /> Insulation for hot water pipe with a minimum thermal resist rice (R-value) of R-3 shall be applied to the <br /> following: <br /> Piping 31; inch (19.1 mm)and larger in nominal diameter <br /> Piping serving more than one dwelling unit. <br /> Piping located outside the conditioned space: <br /> Piping from the water heater to a distribution manifold. <br /> Piping.located under a floor slab. <br /> Buried in piping. <br /> Supply and return piping in recirculation systems other t ian demand recirculation systems. <br /> 25. Blower door test shall be provided before C.O. <br /> 26 A copy of the en er cacls shall be with pern:it at all tines <br /> 27. Co o mal insulation re ort shall be rovided wit ermit be.ore inab <br /> 28. No encePool or screen enclosure .is issued'Wikth s ermit. <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-Florida Building Code 6 h Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.- N ational Electric Code (2016) <br />