My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-22255
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-22255
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/25/2021 10:49:07 AM
Creation date
3/25/2021 10:49:07 AM
Metadata
Fields
Template:
Building Department
Company Name
ZEPHYR LAKES
Building Department - Doc Type
Permit
Permit #
20-22255
Building Department - Name
DR HORTON INC
Address
8015 SAIL CLOVER LN
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r <br /> • <br /> Single Family D elling <br /> Plan Review Com ents <br /> 1. F.F.E.. shall be a minimum of 8" above the road elevation and an engineered_ site plan. <br /> 2. Lots shall be graded to comply with R401:3 of the F.B.C. <br /> 3. Compaction test required if 24" or more of fill dirt is brought in at any one place. <br /> 4. Tie in survey required before pouring concrete. <br /> 5-. Driveways require a R.O.W. use permit. All 4 sides f driveway thru the sidewalk shall have <br /> expansion-material. <br /> 6. All setbacks shall be met. <br /> T All property markers shall be uncovered and marked at time of first inspection. <br /> 8: All A.D.A. requirerrients shall be met: <br /> 9-. No electric,plumbing, mechanical, or framing shall be covered without an inspection and <br /> approval first. <br /> l b: All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation)-. <br /> 1.L Appliances shall not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M303.4 of the F.B. <br /> 12. Water heaters shall comply with section P607.3 oft e F.B.C. <br /> 13. Foundation supports for A/C units shall be raised at east 3" above finished grade. M1308.1 <br /> 14. Return air in all bedrooms. F.B.C. M1620.4 <br /> 15. Smoke detectors are to be installed in accordance wi h R313.1 of the F.B.C. <br /> 16. All glazing requirerrxents are to be in accordance wit R308.4 of the F.B.C. <br /> 17. All means of egress are to be in accordance with R3 1 of the F.B.C. <br /> 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. . <br /> 10. Combination-type AFCI breakers are required at all ocations requiring an AM type breaker. <br /> 20. Carbon monoxide alarms will be required in new co strucfion that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be 111stalled iii accordance with the F.B.C, <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit to unit. This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N.R.C. Codes will be enforced. <br />
The URL can be used to link to this page
Your browser does not support the video tag.