Laserfiche WebLink
23. Tamper-Resistant Receptacles in accordance with 40 .11 of the 2016 N.E.0 <br /> 24. In accordance with the Land Develop_merit Code, lots Ball be sodded before final at least 10 <br /> feet around the structure. <br /> 25. R403.5.3Hot water pipe insulation <br /> Insulation for hot water pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the <br /> folio-wing: . <br /> Piping 3/, inch (1.9.1 mm)and larger in nominal diameter. <br /> Piping serving more than.one dwelling unit. <br /> Piping located.outside the conditioned space. <br /> Piping from the.water heater to a distribution manifold:. <br /> Piping located under a floor slab.. <br /> Buried in piping, <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25. Blower door test shall be provided before C.Q. <br /> 26. A copp of the enerey.cacls shall be with ern:it at all »aes <br /> 2Z Copy o. anal'insulation:re ort-shall be provided ivitiz Peimit be.ore rinaL <br /> 28. No feftee,Pool onscreen enclosure :is issued with:thiy Permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-Florida Building Code 6"'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2016) <br />