Laserfiche WebLink
Manual S Compliance Report Date: <br /> �- wrigh�soft�' p � p Date: <br /> Entire House By: <br /> Progressive Air Systems, Inc Plan: 1828 Cali <br /> 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033 69 <br /> Project • • <br /> For: DR Horton <br /> Lot 3 Blk 7 Abbott Park, Zephyrhills, F <br /> Cooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.2°F Sensible gain: 22201 Btuh Entering coil DB: 75.8°F <br /> Outdoor design WB: 77.1 OF Latent gain: 3647 Btuh Entering coil WB:, 62.9°F <br /> ..Indoor design DB: 75.0°F Total gain: 25848 Btuh <br /> Indoor RH: 50% Estimated airflow: 1000 cfm <br /> Manufacturer's Performance Data.at.Actual Design Conditions <br /> Equipment type: . SplitASHP <br /> Manufacturer: Carrier Model: CH14NB030+FB4C NP030 <br /> Actual airflow: 1000 cfm <br /> Sensible capacity: 23045 Btuh 104%of load <br /> Latent capacity: 4228 Btuh 116%of load <br /> Total capacity: 27273 Btuh 106%of load SHR: -84% <br /> Heating Equipment <br /> Design Conditions <br /> Outdoor design DB: 40.0°F Heat loss: 21992 Btuh Entering coil DB: 69.70F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Condi ions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: CH14NB030+FB4C P030 <br /> Actual airflow: 1000 cfm <br /> Output capacity: 25616 Btuh 1160/6 of load Capacity balance: 33 OF <br /> Supplemental heat required: 0 Btuh Economic balance: -99 OF <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 1000 cfm - <br /> Output capacity: 6.6 kW 102%of load Temp. rise: 2C OF <br /> Meets are all requirements of ACCA Manual S. <br /> ti IItSOft' 2019-Nov-0511:45:57 <br /> A= Wfl 9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1 <br /> 'C'A ...ightsoft Files\Express homes\Cali 4EBB 1828.rup Calc=MJ8 House Front faces: S <br />