My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-22256
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-22256
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/25/2021 10:50:22 AM
Creation date
3/25/2021 10:50:19 AM
Metadata
Fields
Template:
Building Department
Company Name
ZEPHYR LAKES
Building Department - Doc Type
Permit
Permit #
20-22256
Building Department - Name
DR HORTON INC
Address
8029 SAIL CLOVER LN
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- - wrightsoft— Load-Short Form Da <br /> Job: <br /> House By: <br /> Progressive Air Systems, Inc Plan: 1828 Cali <br /> 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC0336 9 <br /> Project • • <br /> For: DR Horton <br /> Lot 3 Blk 7 Abbott Park, Zephyrhills, FL <br /> Design Information <br /> Htg Cig Infiltration <br /> Outside db(OF) 40 91 Method Simplified <br /> Inside db (OF) 70 75 Construction quality Semi-tight <br /> Design TD (OF) 30 16 Fireplaces 0 <br /> Daily range - L <br /> Inside humidity (%) 50 50 <br /> Moisture difference(gr/lb) 26 54 <br /> HEATING EQUIPMENT COOLING EQUIPMENT <br /> Make Carrier Make .Carrier <br /> Trade CARRIER Trade CARRIER <br /> Model CH14NBO30 Cond CH14NBO30 <br /> AHRI ref Coil FB4CNP030 <br /> AHRI r - <br /> Efficiency 8 HSPF Efficiency 11.5 EER, 14 SEER <br /> Heating input SensiblE cooling 22500 Btuh <br /> Heating output 29600 Btuh @ 470F Latent cooling 7500 Btuh <br /> Temperature rise 27 OF Total cooling ling 30000 Btuh <br /> Actual air flow 1000 cfm Actual a r flow 1000 cfm <br /> Air flow factor 0.045 cfm/Btuh Air flow factor 0.045 cfm/Btuh <br /> Static pressure 0.45 in H2O Static p essure 0.45 in H2O <br /> Space thermostat Load se sible heat ratio 0.86 <br /> Capacity balance point=33 OF <br /> Backup: <br /> Input=7 kW, Output=22477 Btuh, 100 AFUE <br /> ROOM NAME Area Htg load GlIg load Htg AVF Clg AVF <br /> (ft2) (Btuh) (Btuh) (cfm) (cfm) <br /> m bed 194 3361 3707 153 167 <br /> living 252 3018 4227 137 190 <br /> kitchen/dining 367 4532 5370 206 242 <br /> bed 3 149 1484 1127 67 51 <br /> bath 2 55 634 292 29 13 <br /> bed 2 158 3573 3026 162 136 <br /> we 21 0 0 0 0 <br /> m bath 114 1350 699 61 31 <br /> wic 66 87 127 4 6 <br /> laundry 39 45 671 2 30 <br /> bed 4 169 1976 1399 90 63 <br /> a/c 18 0 0 0 0 <br /> foyer 218 1934 1555 88 70 <br /> Calculations approved by ACCA to meet all requirements of Manual.J 8th Ed. <br /> wri htsoft° 2019-Nov-0511:45:57 <br /> 1, 9. Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1 <br /> ...ightsoft Files\Express homes\Cali 4EBB 1828.rup Calc=MJ8 House Front faces: S <br />
The URL can be used to link to this page
Your browser does not support the video tag.