Laserfiche WebLink
FORM R405-201.7 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida.Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: li 1828 EI '' ^^..--__ ,^� Builder N me:*DRExpress es <br /> Street: $ � � ` I�WV�C� Permit0 ice: FV� 'L1-City,State,Zip: Zephyrhills, FL, ?)�j�a- n Permit N tubeOwner: Jurisdicti n: low <br /> Design Location: FL,Tampa 17 County: Pasco(Florida Climate Zone 2). <br /> 1. New construction or existing New(From Plans) 9. Wall T 1pes(1710.2 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1404.00 ft2 <br /> b.Frame-Wood,Adjacent R=11.0 306.22 ft? <br /> 3. Number of units,if multiple family _ 1 c.N/A R= ft2 <br /> 4. Number of Bedrooms 4 d.N/A R= ftz- <br /> 5. Is this a worst case? No 10.Ceilin Types (1828.0 sqft.) Insulation Area <br /> a.Und r Attic(Vented) R=30.0 1828.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 1828 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11.Ducts R ft2 <br /> T Windows(167.0 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 356 <br /> a. U-Factor: Dbl, U=0.34 127.00 ft2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Cent al Unit 28.6 SEER:14.00 <br /> c. U-Factor: N/A ft2 <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a. Electric Heat Pump 28.6 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 2.725 ft. <br /> Area Weighted Average SHGC: 0.317 14.Hot water systems <br /> 8. Floor Types (1828.0 sqft.) Insulation Area a.Elect is Cap:50 gallons <br /> a.Slab-On-Grade Edge Insulation R=0.0 1828.00 ftz b. Con 3ervation features EF:0.950 <br /> b.N/A R= ft2 Non <br /> c.N/A R= ft2 15.Credit Pstat <br /> Glass/Floor Area: 0:091 11�7�7 <br /> Total Proposed Modified Loads: 61.33 PASS <br /> Cam+ <br /> Total Baseline Loads: 61.22 <br /> I hereby certify that the plans and specifications covered by Review oft the plans and 04I1iE ST,q?� <br /> this calculation are in compliance with the Florida Energy specifications covered by this <br /> Code. calculation ndicates compliance <br /> with the Flo ida Energy Code. I-V lit, <br /> PREPARED BY: Before construction is completed u� <br /> DATE: this buildinc will be inspected for <br /> compliance with Section 553.908 <br /> I hereby certify that this building, as designed, is in compliance Florida Stat ites. <br /> with the Florida Energy Code. COD WE <br /> OWNER/AGENT:� � C3-- BUILDING OFFICIAL: <br /> DATE: 1 DATE: <br /> JALI <br /> zuzu <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in a cordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 7.00 AC 50(R402.4.1.2). <br /> 11/5/2019 11:45 AM EnergyGaugeO USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th E ition(2017) Compliant Software Page 1.of 4 <br />