Laserfiche WebLink
FORM R405-2017 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: C li 1828 El '' __••--w ,^, Builder N me: DRH Express Homes <br /> Street: $ � ( (' ,{.{��I('� Permit O ice: p <br /> City,State,Zip: Zephyrhills,FL, ?j��j�`�- Permit N mber: <br /> Owner: Jurisdicti n: <br /> Design Location: FL,Tampa '317 County: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 1 9. Wall T pes(1710.2 sgft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Con rete Block-Int Insul,Exterior R=4.1 1404.00 ftz <br /> b.Fra e-Wood,Adjacent R=11.0 306.22 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ftz <br /> 4. Number of Bedrooms 4 d.N/A R= ftz <br /> 5. Is this a worst case? No 10.Ceilin Types (1828.0 sgft.) Insulation Area a.Undi r Attic(Vented) R=30.0 1828.00 ftz <br /> 6. Conditioned floor area above grade(ftz) 1828 b.N/A R= ftz <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ftz <br /> 11.Ducts R ftz <br /> 7. Windows(167.0 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 356 <br /> a. U-Factor: Dbl, U=0.34 127.00 ftz <br /> SHGC: SHGC=0.31 <br /> 12•Cooling systems kBtu/hr Efficiency <br /> b. U Factor: Dbl,U=0.55 40.00 ftz <br /> SHGC: SHGC=0.34 a.Cent I Unit 28.6 SEER:14.00 <br /> c. U-Factor: N/A ftz <br /> SHGC: 13.Heatin systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftz a.Elect is Heat Pump 28.6 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 2.725 ft. <br /> Area Weighted Average SHGC: 0.317 14.Hot wa er systems <br /> a.Elect c Cap:50 gallons <br /> 8. Floor Types (1828.0 sgft.) Insulation Area EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1828.00 ftz b. Con ervation features <br /> b.N/A R= ftz Non <br /> c.N/A R= ftz 15.Credits Pstat <br /> Glass/Floor Area: 0.091 I-/'1a7�7 <br /> Total Proposed Modified Loads: 61 33 PASS <br /> SS <br /> Total Baseline Loads: 61 22 <br /> 1 hereby certify that the plans and specifications covered by Review oft a plans and oks.-T7rT.E Sx � <br /> this calculation are in compliance with the Florida Energy specificatior s covered by this 4V <br /> Code. calculation indicates compliance �jqq�''� '' ;.'01a� <br /> with the Florida Energy Code. ti ii��,::.:'��•. -.;; , ,� O <br /> PREPARED BY: L axP�+*:� completed <br /> Before cons ruction is <br /> DATE: this building will be inspected for 0 <br /> compliance ith Section 553.908 <br /> 1 hereby certify that this building,as designed,is in compliance Florida Stat tes. <br /> with the Florida Energy Code. - ODD WV S� <br /> OWNER/AGENT: BUILDING C <br /> DATE:' 1 l DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that he air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in a cordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 7.00 ACH 0(R402.4.1.2). <br /> 1 1/5/201 9 1 1:45 AM EnergyGaugeO USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 4 <br />