Laserfiche WebLink
h <br /> 4 <br /> Y <br /> V <br /> C <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F. .E.. shall'be a minimum of 8" above the road elev tion and an engineered site plan. <br /> 2! Lots shall be graded:to.comply with R401.3 of the F.B.C. <br /> 3: Cornpactiori test required if 24" or more.of fill dirt is brought in at any one.place. <br /> 4: Tie in survey required before.pouring concrete. <br /> 5. Driveways require.a R.O.W. use permit: All 4 sides f driveway thru the sidewalk shall have <br /> . <br /> expansion material. <br /> 6: All setbacks shall be-met. <br /> 7. All,property markers shall be uncovered.and marked at time of first inspection. <br /> 8. All A:D.A. requirements shall.be met. <br /> 9-. .No electric,plumbing;mechanical,-or framing shall be-covered without an inspection.and <br /> approval first. <br /> 10.. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation): <br /> 11. Appliances shall not be installed in-a location where -u_bject to mechanical_damage unless <br /> protected by approved barriers. M303.4 of the F.B. <br /> 12. Water heaters shall comply with section P607.3 of theF.B.C. <br /> . <br /> 13. Foundation supports for A/C units-shall be raised at 1 ast 3" above finished grade. M1308:1 <br /> 14:.Return air in all bedrooms. F.B.C. M1620.4 <br /> 15. Smoke detectors are to be installed in accordance wi h R313:1 of the F.B.C. <br /> 16. All glazing requirements ate to be in accordance with R308.4 of the F.B:C: <br /> 17. All means of egress are to:be in accordance with RUI 1 of the F.B.C. <br /> 18. `-`Green gypsum board" shall riot be used as a backer in showers or tubs. R702A.2 F.B.C. <br /> 10. Combination-type AFCI breakers are required at all locations requiring an AFCI.type breaker. <br /> 20. Carbon monoxide alarms will be required in new co struchori that uses fossil-burning heating <br /> or appliances or. an attached.garage. They shall be i stalled in accordance with the F.B.C: <br /> 2i. All plumbing,mechanical, and electrical shall be separate from unit to unit. This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced: <br />