Laserfiche WebLink
Q <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to comply with R401.3 'of the F.B.C. <br /> 3. Compaction test required if 24" of more of fill.dirt is brought in at any one place. <br /> 4: Tie in urvey s required before pouring concrete. <br /> 5, Driveways require.a R.O:W. use permit. A114 sides of:driveway thru the sidewalk shall have <br /> . <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> -7: All property markers shall be uncovered,and marked at time of first inspection. <br /> 8. All A.D.A.requirements shall be met. <br /> 9. No electric, plumbing; mechanical, or framing shall.be covered without an'inspection.and <br /> approval first. <br /> 10: All Garages shall comply with section R302.6 of the F.$:C. (Fire Separation). <br /> 11. Appliances shall not be installed in a location where subject to mechanical damage unless <br /> protected.by approved barriers. M303.4 ofthe F.B.0 <br /> 12. Water heaters shall comply with section P607.3 of the F.B:C: <br /> 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308:1 <br /> 14. Return air in all bedrooms. F.B.C. M1620.4 <br /> 1.5. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. <br /> 16. All glazing requirements are to be'in accordance with R308.4.of the RB.C. <br /> 17. All means of egress are to be in accordance with R31I of the F.B.C. <br /> 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. <br /> 10. Combination-type AFCI breakers are required at all locations requiring an AM type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C. <br /> 2-1. All plumbing, mechanical, and electrical shall be separate from unit to unit. This includes all <br /> underground plumbing and electric. <br /> 22. A112016 N.E.C. Codes will be enforced. <br />