20-22387
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-22387
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/22/2021 8:25:46 AM
Creation date
3/29/2021 1:33:13 PM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
20-22387
Building Department - Name
HIDDEN RIVR HO ASSOC INC
Address
39805 HARVEST CREEK LN
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> EBARA Submersible Sewage Pumps DLFU <br /> Specifications <br /> A. General: <br /> Provide submersible sewage pumps suitable for continuous duty operation underwater without loss of watertight <br /> integrity to a depth of 65 feet. Pump system design shall include a guide rail system be such that the pump will be <br /> automatically connected to the discharge piping when lowered into place on the discharge connection.The pump <br /> shall be easily removable for inspection or service, requiring no bolts, nuts, or other fasteners to be disconnected, or <br /> the need for personnel to enter the wetl'well.The motor and pump shall be designed, manufactured, and assembled <br /> by the same manufacturer. <br /> B. Manufacturer: <br /> EBARA International Corporation <br /> C. Pump Characteristics: <br /> Pumps shall conform to the following requirements: <br /> Number of units <br /> Design flow(gpm) <br /> Design TDH (ft) <br /> Minimum shut off head (ft) <br /> RPM 1800 <br /> Maximum HP <br /> Minimum efficiency at design (%) <br /> Minimum power factor at design (%) <br /> Voltage/HZ 208/230V,460V/60 <br /> Phase 3 <br /> D. Pump Construction: <br /> All major parts of the pumping unit(s) including casing, impeller,suction cover,wear rings, motor frame and discharge <br /> elbow shall be manufactured from gray cast iron,ASTM A-48 Class 30. Castings shall have smooth surfaces devoid <br /> of blow holes or other casting irregularities. Casing design shall be centerline discharge with a large radius on the <br /> cut water to prevent clogging. Units shall be furnished with a discharge elbow and 125 lb.flat face ANSI flange.All <br /> exposed bolts and nuts shall be 304 stainless steel.All mating surfaces of major components shall be machined and <br /> fitted with NBR 0-rings where watertight sealing is required. Machining and fitting shall be such that sealing is <br /> accomplished by automatic compression'of 0-rings in two planes and 0-ring contact is made on four surfaces without <br /> the requirement of specific torque limits. Internal and external surfaces are prepared to SPPC-VISI-SP-3-63 then <br /> coated with a zinc-chromate primer.The external surfaces are then coated with a H.B.Teneme-Tar 46H-413 Polyamide <br /> Epoxy-Coal Tar paint <br /> 1. Impellers: <br /> a. For units 2 to 5 HP,the impeller shall be radial single or multi-vane, semi-open design. It shall be dynamically <br /> balanced and shall be designed for solids handling with a long thrulet without acute turns.The inlet edge of the <br /> impeller vanes shall be angled toward the impeller periphery so as to facilitate the release of objects that might <br /> otherwise clog the pump.The 2 to 5 HP impeller design shall also include back pump out vanes to reduce the <br /> pressure and entry of foreign materials into the mechanical seal area. In addition, a lip seal shall be located <br /> behind the impeller hub to further reduce the entry of foreign materials into the seal area. Impellers shall be direct <br /> connected to the motor shaft with a slip fit, key driven, and secured with an impeller bolt.The design shall include <br /> a replaceable cast iron suction cover.iThe suction cover shall be designed such that it may be adjusted to maintain <br /> working clearances and hydraulic efficiencies. <br /> b. For units 71h to 30 HP,the impeller shall be a mixed flow multi-vane semi-open design. It shall be dynamically <br /> balanced and shall be designed for solids handling with a long thrulet without acute turns.The inlet edge of the <br /> impeller vanes shall be angled toward the impeller periphery so as to facilitate the release of objects that might <br /> otherwise clog the pump.The 71h to 30 HP impeller design shall also include back pump out vanes to reduce the <br /> pressure and entry of foreign materials into the mechanical seal area. In addition,a lip seal shall be located <br /> behind the impeller hub to further reduce the entry of foreign materials into the seal area. Impellers shall be direct <br /> laEBARA Fluid Handling <br /> www.pumpsebara.com 2-159 <br /> Eat (t)803 327 5005 • (f}803 327 5097 rev.10/11 <br />