Laserfiche WebLink
TSC 38D - FIBERGLASS ENCLOSURE AND JUNCTION BOX <br /> DUPLEX CQNlROL PANEL—SHALL CONFORM TO FL DEP 64-604.42(A) THREE PHASE WIRING DIAGRAM <br /> CONTROL PANEL SHALL BE TSC MODEL # 38—D IN NEMA 4X U—RED V—WHITE W—BLACK <br /> FIBERGLASS ENCLOSURE. THE PANEL SHALL MEET STATE OF FLORIDA <br /> DEPARTMENT OF ENVIRONMENTAL PROTECTION (DEP), ENVIRONMENTAL <br /> PROTECTION COMMISSION (EPC) AND LOCAL CODE REQUIREMENTS Sp— <br /> GOVERNING PRIVATE LIFT STATIONS. 2 MCB M81 MS i OL'S <br /> t t`i rl - t—PUMPi <br /> FLOAT SWITCHES AND CONTROL SYSTEM SHALL BE UL LISTED 1. <br /> AND INTRINSICALLY SAFE. PANEL SHALL BE UL LISTED. ECB I MB2 MS 2 OL'S <br /> A JUNCTION BOX IS REQUIRED, WITH SHOP POURED SEALS cR s—PUMP2 <br /> BETWEEN BOX AND CONTROL PANEL TO PREVENT SEWER GAS "tp !ENTRY INTO CONTROL PANEL.ELECTRICAL CONTRACTOR TO PROVIDE SERVICE DISCONNECT N <br /> WITH LIGHTNING ARRESTOR MOUNTED PER LOCAL CODES. CONNECTION POINT "A" <br /> THE CONTROL PANEL SHALL BE SUITABLY INSTALLED TO PREVENT F R8 .�j��y-.— <br /> SETTLING OR TIPPING. T �m 8 vM <br /> THERMAL 1 Ts oL'S MS 1 <br /> Bs BID <br /> CONTROL PANEL LAYOUT THEIR 2 TTS OLs s 2 <br /> 813 B14 <br /> F 2 B SEAL PRO <br /> 8E 1 <br /> 1A i B12 13 R314 <br /> F 3 .�-r• SEAL PROBE <br /> ORB CCB MB1 MB2 MCB ECB C'R MOISTURE 1 I to 8 5 1SEAL FAIL 113 PLi <br /> O MOISTURE i2 l 1 R38 SEAL FAIL 2 <br /> AL <br /> 1 2 4 5 6 ALTERNATOR <br /> DUPLEX <br /> OO CONTROLLER <br /> B s1ou12 <br /> F SF2 SEAL FAIL 4*J GENERATOR <br /> INDICATOR INTERLOCK <br /> AH ( ® LIGHTS <br /> ETM1 ETM2 Q <br /> PRESS $OAM AND RUN LIGHTS SAFETY DOOR 4 <br /> T4 ALUMINUM INNER <br /> POWER LIGHT DOOR REINFORCED 7 HI B <br /> SILENCE (4) FLOAT LIGHTS ON ALL SIDES FR 3 FL Al �� A2 <br /> LOCKING HASP L/s � <br /> RyLEAD/LAG FR� R1 A3SELECTOR r;1 L� jASe R1 <br /> FR 1 2 7 <br /> R1DR(GFI) 1 2OR TEST OFF <br /> PANEL WIRING DIAGRAM <br /> TlGHTHOP SEALS0 <br /> URED GAS <br /> ALTERNATOR 1-114" ALL PANELS SHALL CONFORM TO FLORIDA DEP 17-604.400 <br /> EEVV <br /> DUPLEX APPLETON TO PR ENT <br /> SEWER GAS ENTRY (D GENERATOR RECEPTACLE FOR EMERGENCY <br /> INTO PANEL POWER CONNECTION WITH INTERLOCK <br /> OFF LEAo " SURGE PROTECTION AND LIGHTNING <br /> j1 /2 /3 SEPARATE CONDUITS PROTECTION ON ALL INCOMING LEGS <br /> FWAT TUMM&STRIP REQUIRED BY NEC <br /> (1) FLOAT CONTROL CABLES 3 PHASE PROTECTION SHALL BE PROVIDED <br /> NEMA 4X 1 PUMP POWER CABLES <br /> 12 X 12 X 6 Tnat►u� SEAL FAIL DETECTING <br /> FIBERGLASS lim or. p ALTERNATOR DUPLEX CONTROLLER <br /> JUjNCTION BOX <br /> WPuvP1 PwPz TERNIw�L <br /> PANEL AINDM SUB <br /> (5) PUMPS--- __[:�IFIELD INSTALL DUCT SEAL � �— ELAPSED TIME METER FOR PUMP FLOW <br /> TERMINAL STRIPS <br /> SHOWN OPEN FLOATS FURNISH (2) CONDUITS PANEL MANUFACTURER SHALL BE A "UL" LISTED SHOP <br /> FOR CLARITY TO WETWELL 2" MIN <br /> NEC CODE REQUIRES SEPARATE NEUTRAL AND GROUND WIRES <br /> 2 HP = 50 AMP SERVICE <br /> TECHNICAL SALES CORPORATION 3, 5 8c 7 HP = 60 AMP SERVICE <br /> 4621 N. HALE AVE. 10 15 HP = 100 AMP SERVICE <br /> TAMPA, FL 33614 20 & 25 HP = 200 AMP SERVICE <br /> (813) 876-9256 FAX (813) 8764-1 194 TSC38DFG ThreePhose.dwg 1/09 <br />