My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-22387
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-22387
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/22/2021 8:25:46 AM
Creation date
3/29/2021 1:33:13 PM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
20-22387
Building Department - Name
HIDDEN RIVR HO ASSOC INC
Address
39805 HARVEST CREEK LN
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INC MODEL 38-D <br /> DUPLE3 PUMP CONTROL PANEL <br /> Panel meets or exceeds Florida Depiartment of Environmental Protection—FDEP (FAC 17-604) <br /> The control panel shall be UL-508-A Listed and operate (2) electric submersible pumps on a low <br /> voltage (5 V DC)intrinsically safe control system (per FDEP/ 10 STATES STANDARDS) <br /> 1. Fiberglass Enclosure-NEMA 4 X—exterior,water& rain tight—with lockable hasp <br /> The enclosure shall have an aluminum interior"dead front"panel door and a factory supplied back plate that <br /> allows components to be securely mounted. The dead front door shall have (2) elapsed time meters, (2) <br /> pump seal leak detector lights and(1) 115V G.F.I. receptacle. Run lights and control switches shall be <br /> mounted on the DUPLEXOR control dev��ce. (The use of 120-volt controls is not allowed). <br /> 2. Junction Box-NEMA 4X molded fiberglass -is attached to panel with(2) gas tight"Appleton" <br /> seals,mounted and poured with"cheeco"compound to prevent entry of sewer gases into the enclosure. <br /> Terminal strips for float switches and blocks for pump motor connection shall be provided. (Wire nuts are <br /> not allowed). <br /> 3. Circuit Breakers-Thermal magnetic molded case- (1)per pump, control circuit and GFI <br /> receptacle. (Combination IEC type overload/breakers are not acceptable). <br /> 4. Lightning/Transient Surge Protection-plug-in device shall be provided for each leg f <br /> Volta a g ,� <br /> incoming power and shall be mounted onto the exterior side of the enclosure. (Local code may require <br /> additional devices-to be furnished by job''Site electrician) <br /> 5. Motor Starters—NEMA-Rated for 20 starts per hour- open frame, across the line, 120-volt <br /> coil,magnetic starter shall be furnished for each pump motor. The contacts and overload relays shall be <br /> easily replaceable without removing the motor starter from its mounted position. Overload relays,with <br /> individual protection for each leg, shall be block type utilizing melting alloy spindles and shall have visual <br /> trip indication. (Adjustable type-IEC- or definite purpose contactors are not acceptable.) <br /> 6. Voltage Loss Monitor- Single Phase Service- An adjustable 8-pin plug-in voltage monitor <br /> shall be installed for sensing low voltage,�!high voltage and voltage loss. Upon sensing any of the faults,the <br /> control circuit shall de-energize the pumps only and automatically restore service upon return to normal <br /> power. Alarm circuits shall continue to operate provided proper voltage is still active. <br /> 7. Phase Loss Monitor-Three Phase Service-An adjustable 8-pin plug-in phase monitor shall be <br /> installed for sensing low voltage,high voltage,phase loss or reversal. Upon sensing any of the faults,the <br /> control circuit shall de-energize the pumps only and automatically restore service upon return to normal <br /> power. Alarm circuits shall continue to operate provided proper phase and voltage is still active. <br /> 8. High Water Alarm System -Light and Horn-A flashing red light in a weatherproof fixture <br /> shall be mounted to the side of the enclosure. An audible weatherproof alarm bell/horn with an exterior <br /> alarm-silencing button shall de-activate the audible but maintain the visual alarm until the fault is corrected. <br /> i <br /> F/FS/I'SCV/ST/3 8DFGPane1 <br /> Rev 7/04 pgI <br />
The URL can be used to link to this page
Your browser does not support the video tag.