Laserfiche WebLink
• D <br /> Q' <br /> y' <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E:.shall be a minimum of 8"above the road elevation and an engineered site plan. <br /> 2. Lots sfiall.be graded to comply with.R401.3.of the F.B.C. <br /> 3. Compaction test required if 24. or more 0f fill.dirt is brought in at any one place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5. Driveways require a R.O.W.use permit: All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> 7. All,property markers shall be uncovered and marked at time:of first inspection.. <br /> 8: All A.D.A.'requirements shall be met: <br /> R. No electric,:plumbing; mechanical,or framing shall be covered without an inspection and <br /> approval first: <br /> 10: All Garages:shall comply with section R302:6 of the F.B:C. (Fire Separation): <br /> 11. Appliances shall not be installed in a location where subject.to mechanical damage unless <br /> protected by approved barriers. M303:4 of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 of the F.B.C. <br /> 13. Foundation supports for A/C units shall be raised at least 3"above finished grade. M1308A . <br /> 14. Return air in all bedrooms. F.B.C. M1620.4 <br /> 15. Smoke detectors are to be installed in accordance with R3111 of the F.B.C. <br /> 16. All glazing requirements are to be in accordance with R308.4 of the F.B.C: <br /> 17. All means.of egress are to be in accordance with R311 of-the F.B.C. <br /> 18. "Greer'gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. . <br /> 10 Combination-type AFCI breakers are required at all locations requiririg an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage.''They shall be installed in accordance with the F.B.C. <br /> 21. All plumb ing,'mechanical; and electrical shall be separate from unit to unit: This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced. <br /> I <br />