Laserfiche WebLink
D <br /> Q� <br /> N I CJ" <br /> A- <br /> I <br /> n fr <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2. .Lots shall be graded to coriiply with R401.3 of the F:B.C. <br /> 3. Compaction test required if 24": or more.of fill dirt is brought in at any one place. <br /> 4. Tie *in survey required before pouring concrete. <br /> .5. Driveways require.a R.O.W. use permit: All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> 7. All,property markers shall be uncovered and marked at time of first inspection. <br /> 8: All A.D.A.requirements shall be met:.: <br /> 9: No electric,.plumbing; mechanical, or.framing shall be:covered without an inspection and <br /> approval first. <br /> 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). <br /> 11. Appliances.shall not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M303:4 of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 of the E.B.C. <br /> 13. Foundation supports for A/C units.shall be raised at least 3" above-finished grade. M1309. <br /> 14. Return air in all bedrooms. F.B:C- M16MA <br /> 15. Smoke detectors are to be installed in'accordance with R313:1 of the F.B.C. <br /> 16. All glazing requirements are to be in accordance with R308:4 of the F.B:C: <br /> 17. All means of egress are to be in accordance with R311 of the F.B.C. <br /> 18. "Green gypsum,board" shall not be used as a backer in showers or tubs. R702:4:2 F;B'.C. <br /> 10. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C. <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit to unit: This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced. <br />