My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-22583
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-22583
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/17/2021 11:38:51 AM
Creation date
5/17/2021 11:38:50 AM
Metadata
Fields
Template:
Building Department
Company Name
ZEPHYR LAKES
Building Department - Doc Type
Permit
Permit #
20-22583
Building Department - Name
DR HORTON INC
Address
8032 WHEAT STONE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D <br /> Q' <br /> i <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E; shall be a minimum of 8"above the road elevation-and an engineered site plan. <br /> 2. Lots shall.be graded to comply with:R401:3 of the F.B.C. <br /> 3: Compaction test required if 24",or more of fill_dirt is brought in at any one place. <br /> 4: Tie in survey required before_pouring concrete. <br /> 5. Driveways requ ire.a R.O:W. use permit. All 4 sides of driveway.thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> 7: All property.markers shall be uncovered-an-&marked at time of first inspection. <br /> & All A:D.A.'requirements shall.be met: . <br /> 9. No electric,.plumbing,. mechanical, or framing shall be:covered without an inspection.and <br /> approval first. <br /> 10. All Garages shall comply ith section R302.6 of the F.B.-C. (Fire Separation).. <br /> 11. Appliances shall not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M303:4.of the F.B.0 <br /> 12. water heaters.shall comply with section P607.3 of the F:B.C. <br /> 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M 1308.:1. <br /> 14. Return air in all bedrooms. F.B.C. MIKOA <br /> 15. Smoke detectors are to be installed in accordance with R313 J of the F.B.C. <br /> 16., All glazing requirements are to be in- accordance with R308.4 of the F.B.C. <br /> 17. All means of egress are to be in accordance with R311 of the F.B.C. <br /> 18. "Green gypsum board" shall not be used as-a backer-in showers or tubs.R702.4.2 F.B.C. <br /> 19: Combination-type AFCI-breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall_be installed in accordance with the F.B.C: <br /> 21. All plumbing,mechanical, and electrical shall be separate_from unit to unit. This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N:E.C. Codes will be enforced. <br />
The URL can be used to link to this page
Your browser does not support the video tag.