Laserfiche WebLink
Page 3of7 <br /> ® MICROMATIC® STANDARD <br /> ■ ' ' RESPONSE PENDENT <br /> SPRINKLER VK102 (K5.6) <br /> The Viking Corporation,210 N Industrial Park Drive,Hastings MI 49058 <br /> Telephone: 269-945-9501 Technical Services:877-384-5464 Fax: 269-818-1680 Email:techsvcs@vikingcorp.com <br /> Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com <br /> q <br /> RSprinkler Temperature Sprinkler161 <br /> Nominal Maximum Ambient <br /> a+ Bulb C01or. <br /> Cl�as�sifica n �emperatureRat�ing� e C, eiling Temperaturez <br /> Ordinary 135 OF (57'C) 100 OF (38 'C) Orange <br /> Ordinary 155 OF (68'C) 100 OF (38 'C) Red <br /> Intermediate 175 OF (79 'C) 150 OF (65°C) Yellow <br /> Intermediate 200 OF (93'C) 150 OF (65°C) Green <br /> High 286 OF (141 'C) 225 OF (107 'C) Blue <br /> Extra High 360 OF (182 'C) 300 OF (149°C) Mauve <br /> Ultra High 500 OF(260'C) 465 OF (240'C) Black <br /> Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT <br /> Corrosion-Resistant Coatings°: White Polyester and Black Polyester in all temperature ratings. ENT in all temperature ratings ex- <br /> cept 135 OF(57'C). Wax-Coated Brass and Wax over Polyester'for sprinklers with the following temperature ratings: <br /> •155 OF (68'C) Lt. Brown Wax <br /> •175 OF (79'C) Brown Wax <br /> •200 OF(93°C) Brown Wax <br /> •286 OF (141 °C) Dk. Brown Waxs <br /> Footnotes <br /> The sprinkler temperature rating is stamped on the deflector. <br /> 2 Based on NFPA-13.Other limits may apply,depending on fire loading,sprinkler location,and other requirements of the Authority Having Jurisdiction. <br /> Refer to specific installation standards. <br /> 3 Sprinklers of Ultra-High temperature rating are intended for use inside ovens,dryers,or similar enclosures with normal operating temperatures above <br /> 300 OF(149°C).Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 OF(149'C), <br /> response time may be severely retarded. <br /> "The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts.These <br /> tests cannot and do not represent all possible corrosive environments. Prior to installation,verify through the end-user that the coatings are com- <br /> patible with or suitable for the proposed environment. For automatic sprinklers,the coatings indicated are applied to the exposed exterior surfaces <br /> only.Note that the spring is exposed on sprinklers with Polyester and ENT coatings.For ENT coated automatic sprinklers,the waterway is coated. <br /> 'Wax melting point is 170 OF(76°C)for 286 OF(141 °C)temperature rated sprinklers. <br /> Protective Sprinkler jWrench Flat <br /> Clip <br /> � I <br /> j Protective Sprinkler <br /> Y Cap <br /> Figure 1: Standard Sprinkler Wrench 10896WIB <br /> Form No. F_031414 19.02.21 Rev 19.1 <br />