Laserfiche WebLink
Page 4 of 7 <br /> STANDARD RESPONSE <br /> DRY PENDENT STANDARD <br /> ORIFICE SPRINKLERS <br /> The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 <br /> Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com <br /> Visit the Viking website for the latest edition of this technical data page. <br /> Approva'I Chart � (1�L) Temperature K� <br /> Standard Response Standard Orifice Dry Pentlent Sprinklers,�-Finish <br /> Maximum 175 PSI(s1>2 bar,)WWP A1X� Escutcheon(ifapplirable) <br /> Sprinkler Thread Size Nominal Order Length Listings and Approvals° <br /> Base SIN Style K-Factorz Increment (Refer also to Design Criteria below.) <br /> Part No: NPT BSP U.S. metric' Inches mm cULus5 NYC' ® LPCB ' o a <br /> 07740U VK154 Adjustable 1" - 5.6 - 1/2" 12.7 Al A6 Al - -- - - <br /> 07854U -- 25 mm -- 80.6 1/2" 12.7 Al A6 - - -- - - <br /> 09341 VK155 Standard 25 min 80.6 1/2" 12.7 A2 A2 A2 <br /> 0653OU 1" - 5.6 - 1/4" 6.35 B3 B7 B3 - -- - - <br /> 07853U -- 25 mm -- 80.6 1/4" 6.35 B3, B7 - -- -- - -- <br /> 20239U VK158 Adjustable 1" - 5.6 - 1/4" 6.35 - - C9 -- - - <br /> 20374U Recessed __ 25 mm -- 80.6 1/4" 6.35 - - C9 -- - - <br /> 09342 VK159 1 25 mm 80.6 1/4" 6.35 B3 B3 B3 <br /> 07852U VK150 Plain 1" - 5.6 - 1/2" 12.7 A4 A8 A5 - -- - - <br /> 07855U 25 mm 80.6 112" 12.7 A4 A8 - - -- - - <br /> 09343 VK151 Barrel 25 mm 80.6 1/2" 12.7 - A5 A5 A5 <br /> Approved Finishes and "A"Dimensions <br /> 1 - Chrome or White Polyester' sprinkler with a Chrome or White Polyester Sleeve and <br /> Approved Temperature Ratings Escutcheon with"A"dimensions 1-1/2"to 45-1/2"(38.1 mm to 1,156 mm) <br /> pp p g 2-Chrome with"A"dimensions 1-1/2"to 45-1/2"(38.1 mm to 1,156 mm) <br /> A- 155 `F (68 °C), 175 °F (79°C), 200 °F (93 °C), 3-Chrome or White Polyester'with"A"dimensions 3-1/4"to 47-1/2"(82.5 to 1,207 mm) <br /> and 286°F(141 °C) 4-Chrome,White Polyester',or Brass with"A"dimensions 3"to 47"(76.2 to 1,194 mm) <br /> 5-Chrome or Brass with"A"dimensions 3"to 47"(76.2 mm to 1,194 mm) <br /> B-155°F(68°C), 175°F(79°C),and 200°F(93°C) 6-ENT'sprinkler with an ENT'Sleeve and Escutcheon with"A"dimensions 1-1/2"to 45-1/2" <br /> C-155-F(68°C) (38.1 mm to 1,156 mm) <br /> 7-ENT'with"A"dimensions 3-1/4"to 47-1/2"(82.5 to 1,207 mm) <br /> 8-ENT'with"A"dimensions 3"to 47"(76.2 to 1,194 mm) <br /> 9-Chrome with"A"dimensions 3-1/4"to 47-1/2"(82.5 to 1,207 mm) <br /> Footnotes <br /> Part number shown is the base part number.For complete part number,refer to current Viking price list schedule. <br /> s K-Factor applies for standard lengths("A"Dimensions indicated above). <br /> 'Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. <br /> "This chart shows the listings and approvals available at the time of printing.Other approvals may be in process.Check with the manufacturer for any <br /> additional approvals. <br /> 5 Listed by Underwriter's Laboratories for use in the U.S.and Canada. <br /> 6 Accepted for use,City of New York Department of Buildings, MEA 89-92-E,Vol.37. <br /> 'CE Certified,Standard EN 12259-1, EC-certificate of conformity 0832-CPR-S0021. <br /> 'MED Certified,Standard EN 12259-1, EC-certificate 0832-MED-1003. <br /> 'cULus Listed as corrosion resistant. <br /> 9. FINIII All, <br /> Nil 11 <br /> `,� DESIGNtCRITERI�4 �UL. <br /> . ,r ' m , (Alsorefer to Approval Chaitil'above_t) <br /> w. r ,� gyp.•. �.. n_ti-,. <br /> NOTE:When using CPVC fittings with Viking dry sprinklers,use only new Nibco Model 5012-S-BI tees.When selecting other CPVC fittings, <br /> contact Viking Technical Services. <br /> cULus Listing Reauirements: <br /> Standard Dry Pendent Sprinklers are cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for <br /> standard spray pendent sprinklers. <br /> • Designed for use in Light,Ordinary,and Extra Hazard occupancies. <br /> • Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. <br /> • Minimum spacing allowed is 6 ft.(1.8 m)unless baffles are installed in accordance with NFPA 13. <br /> • Locate no less than 4"(102 mm)from walls. <br /> • Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers.The distance shall be measured per- <br /> pendicular to the wall. <br /> • The sprinkler installation and obstruction rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. <br /> IMPORTANT.Always refer to Bulletin Form No. F_091699-Care and Handling of Sprinklers.Also refer to Form No. F_080614 <br /> for general care, installation,and maintenance information.Viking sprinklers are to be installed in accordance with the latest <br /> edition of Viking technical data,the appropriate standards of NFPA, LPCB,APSAD, VdS or other similar organizations, and <br /> also with the provisions of governmental codes, ordinances,and standards,whenever applicable. <br /> Form No. F 071591 18.06.21 Rev 18.1 <br />