Laserfiche WebLink
Schedule �ri, k <br /> Fire Sp, n ler Pipe <br /> • Schedule <br /> Submittal <br /> FM Approved and Fully Listed Sprinkler Pipe SCHEDULE 10 SPECIFICATIONS <br /> Wheatland's Schedule 10 and Schedule 40 <br /> steel fire sprinkler pipe is FM Approved and UL, NOMINAL NOMINAL <br /> C-UL and FM Listed. NPS NOM OD NOM ID WALL WEIGHT UL PIECES <br /> Approvals and Specifications In. i mm I' In. ;� mm Ibs./R.I kg/m CRR* Lik <br /> In. mm <br /> Both products meet or exceed 1% 1.660 42.2 1.442 36.6 .109 2.77 1.81 2.69 7.3 61 <br /> the following standards: -" --" <br /> 1.900 48.3 -1.682 42.7 j ..109 2.77 2.09 ;! 3.11 l; 5.8 61 <br /> • ASTM A135,Type E,Grade A(Schedule 10) - - - - <br /> 2 2.375 60.3 2.157 ! 54.8 .109 2.77 2.64 3.93 4.7 37 <br /> • ASTM A795,Type E,Grade A(Schedule 40) - - <br /> 2% 2.875 73.0 2.635 �I .66.9 J20 f, 3.05 '; 3.53 i1 5.26 3.5 ,i 30 <br /> • NFPA 13 - -- - ---- . . _ .. <br /> 3 3.500 88.9 3.260 82.8 .120 3.05 4.34 6.46 2.6 19 <br /> Manufacturing Protocols - ! -- --- <br /> 4 i; 4.500 114.3 4.260 108.2 120 3.05 1 5.62 1 8.37 j 1.6 i "19 <br /> Schedule 10 and Schedule 40 are subjected l _ _. <br /> to the toughest possible testing protocols to 5 5.563 141.3 5295 134.5 .134 3.40 7.78 11.58 1.5 13 <br /> ensure the highest quality and long-lasting - -- - -- - <br /> performance. 6 6.625 168.3 6.357 i 161.5 .134 1 3.40 1 9.30 'i 13.85 , 1.0 10 <br /> Finishes and Coatings 8 8.625 219A 8.249 209.5 .188 4.78 16.96 25.26 2.1 7 <br /> All Wheatland black steel fire sprinkler pipe 'Calculated using Standard UL CRR formula,UL Fire Protection Directory,Category VIZY. <br /> up to 6" receives a proprietary mill coating to 'The CRR Is a ratio value used to measure the ability of a pipe to withstand corrosion. <br /> Threaded Schedule 40 steel pipe Is used as the benchmark(value of 1.0). <br /> ensure a clean,corrosion-resistant surface that <br /> outperforms and outlasts standard lacquer <br /> coatings.This coating allows the pipe to be SCHEDULE 40 SPECIFICATIONS <br /> easily painted,without special preparation. <br /> Schedule 10 and Schedule 40 can be ordered in NOMINAL NOMINAL <br /> black,or with hot-dip galvanizing,to meet NPS NOM OD NOM ID WALL WEIGHT UL PIECES <br /> FM/UL requirements for dry systems that meet In. : �mm _ mm I; In. mm Ibs./ ff kg/m CRR. LIft <br /> the zinc coating specifications of ASTM A795 -' - --"I - �-- -- - - <br /> or A53.All Wheatland galvanized material is 1 1.315 33.4 1.049 26.6 .133 3.38 1.68 2.50 1.00 70 <br /> also UL Listed. _-- <br /> 1'/a 1.660 �1 42.2 ' 1.380 35.1 .140 y "3.56 2.27 I 3.39 1.00 51 <br /> Product Marking 1'h 1.900 48.3 1.610 40.9 345 3.68 2.72 4.05 1.00 44 <br /> Each length of Wheatland fire sprinkler <br /> 2 2.375 :1 60.3 2.067 52.5 .154 .i 3.91 3.66 5.45 1.00 i 30 <br /> pipe is continuously stenciled to show - _�___ _ _- ._. _ ... <br /> the manufacturer,type of pipe,grade,size 'Calculated using Standard UL CRR formula,UL Fire Protection Directory,Category VIZY. <br /> and length.Barcoding is acceptable as a 'The CRR Is a ratio value used to measure the ability of a pipe to withstand corrosion. <br /> supplementary identification method. Threaded Schedule 40 steel pipe Is used as the benchmark(value of LO). <br /> ul C u� FM <br /> L APPROVED <br /> PROJECT: CONTRACTOR: DATE: <br /> ENGINEER: SPECIFICATION REFERENCE: SYSTEM TYPE: <br /> LOCATIONS: COMMENTS: <br /> ❑ BLACK ❑ HOT-DIP GALVANIZED <br /> Wheatland Tube 00 South Dock StreetWheatland rube <br /> 800.257.8182 • info@wheatiand.comcorn JMC STEEL GROUP <br />