Laserfiche WebLink
INSULATION FASTENER&PLATE TABLE FOR MECHANICALLY ATTACHED SYSTEMS(TABLE 1 OF 2) <br /> For insulation attachment attachment use Table 1 to determine the number of fasteners per board and Table 2 to determine the <br /> proper fastener and plate. <br /> Number of Fasteners per Board <br /> Insulation Type Board Size Thickness <br /> Field Perimeter Corner <br /> 4'x4' Any 4 4 4 <br /> (1.2mx2.4m) <br /> Pol 'so 4'x8' W'4.2" 6 6 6 <br /> (1.2mx2.4m) (13-30mm) <br /> 4'x8' >_1.3" 5 5 5 <br /> (1.2 m x 2.4 m) (33 mm) <br /> 4'x4' <br /> Perlite (1.2 m x 2.4 m) Any 4 4 4 <br /> 4'x4' Any 4 4 4 <br /> (1.2mx2.4m) <br /> Wood Fiber <br /> 4'x8' Any 6 6 6 <br /> (1.2mx2.4m) <br /> 4'x4' Any 4 4 4 <br /> (1.2mx2.4m) <br /> Extruded Polystyrene' 4'x8' W"4.2" 6 6 6 <br /> (1.2mx2.4m) (13-30mm) <br /> 4'x8' >1.3" 5 5 5 <br /> (1.2mx2.4m) (33mm) <br /> 4'x4' Any 4 4 4 <br /> (1.2mx2.4m) <br /> Expanded Polystyrene' 4'x8' 'h"4.2" 6 6 6 <br /> (1.2mx2.4m) (13-30mm) <br /> 4'x8' >1.3" 5 5 5 <br /> (1.2mx2.4m) (33mm) <br /> Fanfold <br /> (TPO or PVC Fanfold' 3/8 m ) <br /> (10 mm 2-1-2-1-2 2-1-2-1-2 2-1-2-1-2 <br /> Fleece-back only) <br /> Gypsum Board' 4'x8' 1/4"-5/8" 6 6 6 <br /> (1.2mx2.4m) (6-16mm) <br /> 'Smooth PVC must have a 3/6 oz.(85/170 gr)polymat separator sheet.Fleece-back PVC is acceptable. <br /> 2 Fanfold attachment spacing is for each 2'x 4' (610 rum x 1.2 m)section. <br /> 3Includes approved DensDeck®and SECUROCK®roof board products. <br /> 23 <br />