Laserfiche WebLink
INSULATION FASTENER&PLATE TABLE FOR MECHANICALLY ATTACHED SYSTEMS(TABLE 2 OF 2) <br /> Deck Type Fastener Type Plate Type Penetration(min.) <br /> Drill-Tec'"#12 Fastener <br /> steel, Drill=1ec�'3 (76 mm)steel Plate 3/4"(19 rum) <br /> gauge) through the deck <br /> Drill-'Ikc'"#14 Fastener <br /> Drill-Tec'"#12 Fastener <br /> Wood 1"(25 mm)thread <br /> (Plywood,OSB and Plank) Drill-Tec'"#14 Fastener Drill-Tec'"3"(76 mm)Steel Plate into/through the deck <br /> Drill-Tec—HXD#15 Fastener <br /> Drill-Tec'"CD-10 Fastener Drill-Tec-3"(76 min)Steel Plate 1 (25 mm)shank <br /> into the deck <br /> Structural Concrete <br /> Drill-Tec—#14 Fastener Drill-Tec'"3"(76 mm)Steel Plate 1"(25 mm)thread <br /> into the deck <br /> Drill-Tec—#12 Fastener <br /> Lightweight Insulating 3/4"(19 mm)thread <br /> Concrete(LWIC) Drill-Tec'"#14 Fastener Drill-Tec'"3"(76 mm)Steel Plate through steel form <br /> Drill-Tec'"M#15 Fastener <br /> Drill-Tec'"Polymer Drill-Tec'"3"(76 mm)GypTecTM Plate <br /> Gypsum Concrete and GypTec"'Fastener 11/2"(38 mm) <br /> Cementitious Wood Fiber <br /> thread into the deck <br /> (rectum) <br /> Drill-Tec'"LD Fastener Drill-Tec'"3"(76 mm)LD Plate <br /> '24-26 gauge decks require a GAF Field Services Manager's or Director's approval.GAF does not approve the use of metal panels as a roof deck. <br /> 24 <br />