Laserfiche WebLink
-A <br /> DESIONCOMSIDERATIONS <br /> APPLICATION <br /> MECHANICALLY 1 / • o MIS <br /> •, : PVC <br /> 4. EnergyGuard—NH Polyiso Insulation is made of glass- 6. Expanded Polystyrene Insulation(EPS)with plastic facer <br /> reinforced cellulosic felt facers bonded to a core of non- meets or exceeds the requirements for ASTM C578,Type IX <br /> halogenated polyisocyanurate foam.Meets or exceeds the [min.25 psi(173 kPa)compressive strength]. <br /> requirements of ASTM C1289 Type II,Class 1,Grade 2(20 7 Extruded Polystyrene Insulation(XPS)meets or exceeds <br /> psi),and available in Grade 3(25 psi). the requirements for ASTM C578,Type IV[min.25 psi(173 <br /> 5. EnergyGuard—NH HD Ultra Polyiso Insulation is made of kPa)compressive strength]. <br /> coated glass facers bonded to a core of non-halogenated <br /> polyisocyanurate foam.Meets or exceeds the requirements <br /> of ASTM C1289 Type I1,Class 2,Grade 2(20 psi),and 2.09 Cover/Re-cover Boards <br /> available in Grade 3(25 psi). A.Cover/Re-cover boards of the following types listed below are <br /> 6. EnergyGuard—Perlite roof insulation is composed of acceptable for use in roofing systems guaranteed by GAF.Board <br /> expanded perlite particles,selected binders and cellulose size can be 4'x 4'or 4'x 8' (1.21 m x 1.21 m or 1.21 m x 2.4 m) <br /> fibers that meets or exceeds the requirements of ASTM panels for mechanical attachment and 4'x 4'or 4'x 8' (1.21 m <br /> C728,Type I. x 1.21 m or 1.21 m x 2.4 m)for adhered attachment and tapered <br /> 7. EnergyGuard—Tapered Perlite roof insulation is composed systems,except for fanfold re-cover board,which comes in 2' (610 <br /> of expanded perlite particles,selected binders and cellulose mm)x 4' (1.21 m)sections with a 50' (15.2 m)total length. <br /> fibers that meets the requirements of ASTM C728,Type I. 1. EnergyGuard—HD Polyiso Insulation is a W' (12.7 mm) <br /> 8. Expanded Polystyrene Insulation(EPS)with plastic facer thick high-density polyiso cover board made of coated <br /> meets or exceeds the requirements of ASTM C578,Type II Oass-fiber mat facers bonded to high-density closed <br /> nominal 1.5 lb.(42 g/cm3)density and minimum 15 psi cell polyisocyanurate foam cores.Meets or exceeds the <br /> (110 kPa)compressive strength. requirements of ASTM C1289 Type 2,Class 4,Grade 1(80 <br /> psi). <br /> 9. Extruded Polystyrene Insulation(XPS)meets or exceeds the 2. EnergyGuard-HD PLUS Polyiso Insulation is a'V' (12.7 <br /> requirements of ASTM C578,Type II nominal 1.5 lb.(42 g/ mm)thick high-density polyiso cover board made of <br /> cm')density and minimum 15 psi(110 kPa)compressive coated glass-fiber mat facers bonded to high-density closed <br /> strength. cell polyisocyanurate foam cores.Meets or exceeds the <br /> requirements of ASTM C1289 Type 2,Class 4,Grade 2(110 <br /> 2.08 High Traffic Applications psi)- <br /> A.Insulation boards of the types listed below are acceptable for use 3• EnergyGuard-Barrier Polyiso Insulation consists of coated <br /> in roofing systems guaranteed by GAF.The actual minimum glass-fiber and a special coated glass-fiber laminated to a <br /> thickness of insulation will depend on flute spacing.Refer to closed-cell polyisocyanurate foam core.Meets or exceeds <br /> specific Product Data Sheets for further information.Board size the requirements of ASTM C1289 Type 2,Class 4,Grade 2. <br /> can be 4'x 4'or 4'x 8' (1.2 m x 1.2 m or 1.2 m x 2.4 m)panels 4. USG SECUROCK®Brand Gypsum-Fiber Roof Board is a <br /> for mechanical attachment high-performance,non-combustible,moisture and mold <br /> 1. EnergyGuard—Polyiso Insulation is made of glass resistant roof board that meets the requirements of ASTM <br /> fiber-reinforced cellulosic felt facers bonded to a core of C1278. <br /> polyisocyanurate foam.Meets the requirements of ASTM 5. DensDeck®and DensDeck®Prime Roof Board is made of <br /> C1289 Type 11,Class 1,Grade 3(25 psi)min. glass mat facings front and back that are embedded into a <br /> 2. EnergyGuard—Tapered Polyiso Insulation is made of glass water-resistant and moisture-resistant treated gypsum core. <br /> fiber-reinforced cellulosic felt facers bonded to a core of Meets the requirements of ASTM C1177. <br /> polyisocyanurate foam.It is readily available in various 6.STRUCTODEK®High Density Fiberboard Roof Insulation <br /> profiles such as the most popular and efficient tapers, Cover Board with Primed Red Coating incorporates a non- <br /> 1/8:12(19/6),1/4:12(29/6),and 1/2:12(49Q.Meets or asphaltic Primed Red Coating integrated on the surface <br /> exceeds the requirements of ASTM C1289 Type II,Class 1, board that meets the requirements of ASTM C208,Type II, <br /> Grade 3(25 psi).Maximum board size is 4'x 4' (1.21 m x Grade 1 and Grade 2. <br /> 1.21 m). 7.EnergyGuard—Perlite roof insulation is composed of <br /> 3. EnergyGuard—Ultra Polyiso Insulation is made of expanded perlite particles,selected binders and cellulose <br /> coated glass-fiber mat facer laminated to a closed- fibers that meets the requirements of ASTM C728,Type I. <br /> cell polyisocyanurate foam core.Meets or exceeds the 8.Extruded Polystyrene Insulation Fan-fold Re-cover Board <br /> requirements of ASTM C1289 Type II,Class 2,Grade 3(25 <br /> psi). 3/8"(9.5 mm)with plastic facer meets or exceeds the <br /> requirements for ASTM C578,Type IV[min 25 psi(173 <br /> 4. EnergyGuard—NH Polyiso Insulation is made of glass- kPa)compressive strength]. <br /> reinforced cellulosic felt facers bonded to a core of non- 9•Extruded Polystyrene Insulation Re-cover Board 1/2" (13 <br /> halogenated polyisocyanurate foam.Meets or exceeds the mm)with plastic facer meets or exceeds the requirements <br /> requirements of ASTM C1289 Type II,Class 1,Grade 3(25 for ASTM C578,Type IV[min 25 psi(173 kPa)compressive <br /> psi). strength]. <br /> 5. EnergyGuard—NH HD Ultra Polyiso Insulation is made of <br /> coated glass facers bonded to a core of non-halogenated <br /> polyisocyanurate foam.Meets or exceeds the requirements <br /> of ASTM C1289 Type II,Class 2,Grade 3(25 psi). <br /> 40 <br />