My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-22756
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-22756
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2021 9:57:12 AM
Creation date
6/15/2021 9:57:12 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
20-22756
Building Department - Name
LENNAR HOMES LLC
Address
3089 LYTTON HALL DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Single Family Dwelling <br /> Plan Review Comments <br /> 1. V.F.E. shall be a inim'mum of 8"above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to comply with R401.3 of the F.B.C. <br /> 3. Compaction test required if 24"or more of fill dirt is brought in at any one place. <br /> 4. Tie in survey required before pouring concrete. <br /> 5. Driveways require a R.O.W.use permit: All 4 sides of driveway thin the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> 7. All.property markers shall be uncovered and marked at time of first inspection. <br /> 8: All A.D.A.'requirements shall be znet: <br /> 9-. No electric,.plumbing, mechanical, or framing shall be covered without an inspection and <br /> approval first. <br /> 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). <br /> 11.Appliances shall not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M303.4 of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 of the F.B.C. <br /> 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M 1308:1 <br /> 14. Return air in all bedrooms. F.B.C. M1620A <br /> 15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. <br /> 16: All glazing requirements are to be in accordance with R308.4 of the F.&C. <br /> 17. All means of egress are to be in accordance with R311 of the F.B.C.. <br /> 18. "Green gypsumboard" shall not be used as a backer in showers or tubs. R7o2.4.2 F B.C. <br /> 191 Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. <br /> 20.'Carbon monoxide alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C. <br /> 21. All plurilbing,inechariical, and electrical shall be separate from unit to unit: This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced. <br />