Laserfiche WebLink
_r <br /> y <br /> 23. Tamper-Resistant Receptacles in accordance with 406.11 ofthe 2016-N.E:C <br /> 24. In accordance with the Land Development Code, lots shall be sodded before final at least 10 <br /> feet around'the structure. <br /> 25: R403.5.3Ho(Waterpipe insulation <br /> Insulation for hot water pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the <br /> following: <br /> Piping 3/. inch (19'.1 mm) and larger innominal diameter.. <br /> Piping serving more than.one dwelling unit. <br /> Piping Jocated outside the conditioned space: <br /> Piping from the mates heater to a-distribution manifold:, <br /> Piping.located under a floor slab. <br /> Buried in piping. <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25. Blower door test shall be provided before C.O: <br /> 26.A copy of the enerjzy carts shall be with permit at all times <br /> 27. Copy of final'insulation-report shall be provided ivith perfnit before&nal <br /> 28 No fence,pool onscreen enclosure Is issued with:this permit <br /> F.F.E.-Finished Floor Elevation <br /> RB.C--Florida Building Code 6t'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) <br />