Laserfiche WebLink
D <br /> Q <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E.- shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2. Lots shall b 'graded to comply with R401:3 of the F.B.C: <br /> 3. Compaction test required if 24".or more of fill dirt is brought in at any one-place. <br /> 4. Tie in survey required before pouring concrete. <br /> 5. Driveways require a R..O:W. use permit. A114 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> 7: All property markers shall be uncovered and marked at time of first inspection. <br /> 8: All A:D.A.'requirements shall be met. <br /> 9- No electric,-plumbing;mechanical, or framing shall.be_covered without an inspection and <br /> . e .. . . <br /> approval first-. <br /> 10: All Garages shall comply with section R302.6 of the R13.C. (Fire Separation): <br /> 1.L Appliances shall not be installed in 'a-location where subject to mechanical damage unless <br /> protected by approved barriers. M303:4 of the F B.0 <br /> 12. Water heaters shall comply with section P607.3 of the F.B.C. <br /> 13. Foundation supports for A/C units.shall.be raised at least 3" above finished grade. M1308.:1.. <br /> 14. Return air in all bedrooms. F.B.C. M16204 <br /> 15. Smoke detectors.are to be installed in accordance with R313.1 of the F.B.C_. <br /> 16. All glazing requirements are to be in accordance with R308.4 of the F.B:C: <br /> 17. All means.of egress are.to be in accordance'with R311 of the R.B.C. <br /> 18. `-`Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F-.B.C. <br /> 10. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C. <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit to unit. This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced: <br />