Laserfiche WebLink
' D <br /> 1 <br /> Q' <br /> • 1 � <br /> Single Family. DwellfiI2 <br /> Plan Review Comments <br /> L. F:RE.shall.:be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2: .Lots shall be graded to.comply-with R401-3-of the F:B.C:- <br /> 3: Compaction test required.if 24 or more.of fill dirt is brought in at any one place. <br /> 4. Tie i`n survey required:before pouring concrete: . <br /> 5. Driveways require.a R.O.M. use permit: All 4 sides of driveway thru the sidewalk shall have: <br /> expansion material.:: <br /> 6: All setbacks shall be met. <br /> 7. All,property markers shall be uncovered.and.marked at time.of first inspection. <br /> 8: All A.D.A.requirements shall be.met <br /> 9: No electric,.plumbing;mechanical, or framing shall.be covered without an inspection and <br /> approval first: <br /> 10. All Garages shall comply with section.R302:6 of the F.B.C. (Fire Separation): <br /> 11. Appliances.shall not be_installed_in a location where subject to mechanical.damage unless <br /> protected by approved barriers. M303:4 of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 of the F:B.C: <br /> 13. Foundation.supports for A/C units..shall.be raised at least"3" above finished grade: M1-308.:1 <br /> . 14. Return air in all bedrooms: F.B:C. M1620:4 <br /> 1.5. Smoke detectors are to be installed in accordance with R3-13:1 of.the F.B.C. <br /> 16.All-glazing requirements are to be in accordance-with R308.4 of the RB.C: <br /> 17. All means.of egress are to be in accordance with R311 of the F.B.C: <br /> 18. "Green_gypsum.board"-shall not be used as a backer in showers or tubs. R702:4.2 P.B.C. <br /> 19: Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or aii attached garage. They shall be installed in accordance with the F.B.C: <br /> 21..All plumbing,mechanical; and electrical shall be separate:from unit to unit. This includes-all <br /> underground plumbing and "electric. <br /> 22. All 2016 N.E.C. Codes will be enforced: <br />