Laserfiche WebLink
23. Tamper- Resistant Receptacles in accordance with 406.11 Of the 2016 N.E.-C <br /> 24. In accordance with the Land Development Code, lots shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25. R403.5.3Hot Water,pipe insulation <br /> insulation for hot water pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the <br /> following'-. <br /> Piping V. inch (19.1.mm)and larger in nominal diameter. <br /> Piping;serving more than one dwelling unit. <br /> Piping located outside the conditioned space. <br /> Piping from the:water heater to.a distribution manifold., . <br /> Piping-located under.a floor slab. <br /> Buried in piping, <br /> Supply and return piping in recirculation systems other than'demand recirculation systems. <br /> 25. Blower door test shall be provided before C.O: <br /> 26. A copy of the enemy:cacls shall be with permit at all tunes <br /> . . <br /> 27.. Copy,of final insulation report shall be provided with permit before fnal <br /> 28. No fence,pool or screen enclosure is issued with ahis permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-.Florida Building Code 6t'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.=Americans with Disabilities Act N.E.C.-National Electric Code (2016) <br />