Laserfiche WebLink
I, Manual S Compliance Report Job: <br /> +P- wrightsoft® Date: <br /> Entire House By: <br /> Progressive Air Systems, Inc Plan: Roble2447 <br /> 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 <br /> Pro'ect 10formati0h, <br /> For: DR Horton <br /> Lot 11 Blk 10 Abbott Park, Zephyrhills, FL <br /> �C,00fin.g Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.2°F Sensible gain: 28833 Btuh Entering coil DB: 76.6°F <br /> Outdoor design WB: 77.1 OF Latent gain: 4479 Btuh Entering coil WB: 63.3°F <br /> Indoor design DB: 75.0°F Total gain: 33312 Btuh <br /> Indoor RH: 50% Estimated airflow: 1367 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: CH14NB042****A+FB4CNF042L <br /> Actual airflow: 1367 cfm <br /> Sensible capacity: 32479 Btuh 113%of load <br /> Latent capacity: 5666 Btuh 126%of load <br /> Total capacity: 38145 Btuh 115%of load SHR: 85% <br /> Reafing Equipment <br /> Design Conditions <br /> Outdoor design DB: 40.0°F Heat loss: 24826 Btuh Entering coil DB: 69.3°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: CH14NB042****A+FB4CNF042L <br /> Actual airflow: 1367 cfm <br /> Output capacity: 37291 Btuh 150%of load Capacity balance: 29 OF <br /> Supplemental heat required: 0 Btuh Economic balance: -99 OF <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 1367 cfm <br /> Output capacity: 7.2 kW 99%of load Temp. rise: 50 OF <br /> Meets are all requirements of ACCA Manual S. <br /> .L wri htsoft° 2020-Mar-1613:13:18 <br /> �. 9 Right-Suite®Universal 2017 17.0.21 RSU25554...ghtsoft Files\Express homes\Robie 3EFB 2447.rup Calc=MJ8 House Front faces: W Page 1 <br />