My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-22779
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-22779
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2021 10:11:35 AM
Creation date
6/15/2021 10:11:32 AM
Metadata
Fields
Template:
Building Department
Company Name
ZEPHYR LAKES
Building Department - Doc Type
Permit
Permit #
20-22779
Building Department - Name
DR HORTON INC
Address
7796 DAVIE RAY DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
® Load Short Form Job: <br /> wrightsoft Date: <br /> Entire House By: <br /> Progressive Air Systems, Inc Plan: Robie2447 <br /> 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 <br /> For: DR Horton <br /> Lot 11 Blk 10 Abbott Park, Zephyrhills, FL <br /> Design, • e <br /> Htg Clg Infiltration <br /> Outside db(OF) 40 91 Method Simplified <br /> Inside db(OF) 70 75 Construction quality Semi-tight <br /> Design TD (OF) 30 16 Fireplaces 0 <br /> Daily range - L <br /> Inside humidity (%) 50 50 <br /> Moisture difference(gr/lb) 26 54 <br /> HEATING EQUIPMENT COOLING EQUIPMENT <br /> Make Carrier Make Carrier <br /> Trade CARRIER Trade CARRIER <br /> Model CH14NB042****A Cond CH14NB042****A <br /> AHRI ref Coil FB4CNF042L <br /> AHRI ref <br /> Efficiency 8.2 HSPF Efficiency 11.0 EER, 14 SEER <br /> Heating input Sensible cooling 30750 Btuh <br /> Heating output 38500 Btuh @ 47OF Latent cooling 10250 Btuh <br /> Temperature rise 26 OF Total cooling 41000 Btuh <br /> Actual air flow 1367 cfm Actual air flow 1367 cfm <br /> Air flow factor 0.055 cfm/Btuh Air flow factor 0.047 cfm/Btuh <br /> Static pressure 0 in H2O Static pressure 0 in H2O <br /> Space thermostat Load sensible heat ratio 0.87 <br /> Capacity balance point=29 OF <br /> Backup: <br /> Input= 7 kW Output=24633 Btuh 100 AFUE <br /> ROOM NAME Area Htg load Clg load Htg AVF Clg AVF <br /> (ft2) (Btuh) (Btuh) (cfm) (cfm) <br /> bed2 161 2793 1994 154 95 <br /> living/dining 376 5534 6959 305 330 <br /> foyer 190 4073 2046 224 97 <br /> bath2 59 939 328 52 16 <br /> kitchen 210 1074 2530 59 120 <br /> pantry 39 843 351 46 17 <br /> bed5 156 1473 2207 81 105 <br /> bed4 162 1502 2238 83 106 <br /> bed3 152 829 1708 46 81 <br /> chase 6 8 15 0 1 <br /> bath3 69 344 363 19 17 <br /> laundry 60 417 1102 23 52 <br /> M bath 116 640 649 35 31 <br /> toilet 23 45 63 2 3 <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> A wri9 htsoft° Right-Suite®Universal 2017 17.0.21 RSU25554 2020-Mar-1613:13:18 <br /> Z <br /> wdk ...ghtsoft Files\Express homes\Roble 3EF8 2447.rup Calc=MJ8 House Front faces: W Page 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.