Laserfiche WebLink
L <br /> D <br /> Q <br /> V <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E..shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to comply with R401.3.of the F. <br /> 3: Compaction test required if 24"or'more of fill.dirt is brought in at any one place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5. Driveways require.a R.O:w. use permit. All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> 7. All.propertv.markers shall be uncovered-and marked at time pf first inspection. <br /> & All A.D.A.-requirements shall be met: <br /> 9. No electric,plumbing, mechanical, or framing shall.be_covered without an inspeetion.and <br /> approval first. <br /> 10. All Garages shall comply with section R302'.6 of the F.B.C.'(Fire Separation). <br /> 11. Appliances shall not be installed in a location where-subject to mechanical damage unless <br /> protected by approved barriers. M303_.4 of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 of-the F.B.C. <br /> 13. Foundation supports for A/C units shall.be raised at least 3" above finished grade. M1308.1 <br /> 14. Return air in all bedrooms: F.B.C. M162.OA <br /> 1.5. Smoke detectors are to be installed_ in accordance with R313.1 of the F.B.C. <br /> 16. All glazing requirements are to be in accordance"with R308A of the F.B.C. <br /> 17. All means of egress are to be in accordance with R311. of the F.B.C. <br /> 18. "Gr"een.gypsum board" shall not be used as a banker in showers or tubs.R702.4.2 F.B.C. <br /> 106 Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage.- They shall be installed in accordance with the T.B.Ci <br /> 21. All plumbing, mechanical, and electrical shall be separate from unit to unit. This includes all <br /> - underground plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced: <br />