Laserfiche WebLink
23. Tamper-Resistant Receptacles in accordance with 406.11 of the 2016 N.E:C <br /> 24. In accordance with the Land Development Code, lots.shall be sodded before final at least 10 <br /> feet around the structure: <br /> .25-. R403.5,3Hot water.pipe insulation. <br /> Insulation for hot.water pipe with a minimum thermal resistance.(R-value) of R-3 shall.be applied to the- <br /> following: <br /> Piping.3/4 inch (19.1 mm) and larger in nominal diameter. <br /> Piping serving more than one dwelling unit. <br /> Piping located outside the conditioned space. <br /> Piping from the:water'heater to:a=distribution manifold:. <br /> Piping:located under a floor slab:- <br /> Buried in piping, <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> -25. Blower.door test shall be provided.belfore C.O; <br /> 26. A copy of the-energy cacls shall be-with permit at all times <br /> 27 COV.of rnal insulation-report shall be provided with permit before rinah <br /> 28. No fence, pool or screen enclosure -is issued with ihispermit <br /> F.F.E.-Finished Floor Elevation <br /> RB.C-:Florida Building Code Oh Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act . N.E.C.-National Electric Code(2016) <br />