<br /> TABLE 21: STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER
<br /> SYSTEM TYPE D-1: MECHANICALLY ATTACHED ROOF COVER
<br /> Deck- ` = Insulation(Note 14) Roof Cover; MDP
<br /> System No.
<br /> (Note 1) Type Attach Membrane; Fasteners Attachment (psf)
<br /> EVERGUARD TPO:
<br /> S 314.
<br /> Min.22 ga.,type B, One or more layers,any Prelim. EverGuard TPO Drill-Tec XHD with Drill-Tec 2 3/8 in.Barbed 18-inch o.c.within 6-inch wide laps spaced 54-inch o.c. -30.0
<br /> Grade 80 steel combination,min.1-inch attach XHD Plates and sealed with a 1.5-inch heat weld.
<br /> Barbed
<br /> Min.22 ga.,type B, One or more layers,any Prelim. Drill-Tec XHD with Drill-Tec 2-3/8 in. 12-inch o.c.within 6-inch wide laps spaced 114-inch
<br /> S-315. Grade 33 steel combination,min.1.5-inch attach EverGuard TPO XHD Plates or Drill-Tec Eyehook AccuSeam o.c.and sealed with a 1.5-inch Beat weld. -30.0
<br /> Plates
<br /> Min.22 ga.,type B, One or more layers,any Prelim. Drill-Tec XHD and Drill-Tec 2 in.Double Barbed 12-inch o.c.in rows spaced maxi 114-inch o.c. An 8-
<br /> S-316. Grade 33 steel combination,min.1.5-inch attach EverGuard TPO XHD Plates,Drill-Tec 2-3/8 in.Barbed XHD inch wide cover strip is heat welded over the stress -30.0
<br /> Plates,Drill-Tec Eyehook AccuSeam Plates plates.
<br /> Min.22 ga.,type B,
<br /> One or more layers,any Prelim. Drill-Tec SXHD with Drill-Tec 2 3/4 in.Barbed 12-inch o.c,within 6-inch wide laps spaced 138-inch
<br /> S-317. Grade 33 steel;4 ft combination,min.1-inch attach EverGuard TPO SXHD Plates o.c.and sealed with a 1.5-inch Beat weld. -30.0
<br /> span
<br /> Min.20 ga.,type B, j
<br /> One or more layers,any Prelim. Drill-Tec SXHD with Drill-Tec 2 3/4 in.Barbed 12-inch o.c,within 6-inch-wide laps spaced 138-inch
<br /> 5-318: Grade 33 steel;5 ft combination,min.1-inch attach EverGuard TPO SXHD Plates o.c.and sealed with a 1.5-inch Beat weld. 30.0
<br /> span i
<br /> Min.18 ga.,type B,
<br /> One or more layers,any Prelim. Drill-Tec SXHD with Drill-Tec 2 3/4 in.Barbed 12-inch o.c.within 6-inch wide laps spaced 138-inch
<br /> S-319. Grade 33 steel;6 ft combination,min.1-inch attach EverGuard TPO SXHD Plates o.c.and sealed with a 1.5-inch Beat weld. -30.0
<br /> span i
<br /> Min.22 ga.,type B, One or more layers,any Prelim. Drili-Tec XHD or Drill-Tec SXHD with Drill-Tec 2 12-inch o.c,within 6-inch wide laps spaced 138-inch
<br /> S-320. Grade 80 steel;6 ft combination,min.1-inch attach EverGuard TPO 3/4 in.Barbed SXHD Plates o.c.and sealed with a 1.5-inch heat weld. -30.0
<br /> span
<br /> Min.22 ga.,type B, One or more layers,any Prelim. Drill-Tec XHD with Drill-Tec 2 in.Double Barbed 12-inch o.c.within 6-inch wide laps spaced 90-inch o.c.
<br /> 5-321. Grade 33 steel combination,min.1-inch attach EverGuard TPO XHD Plates and sealed with a 1.5-inch heatjweld. -37.5
<br /> Min.22 ga.,type B, One or more layers,any Prelim. Drill-Tec SXHD with Drill-Tec 2 3/4 in.Barbed 12-inch o.c,within 6-inch wide laps spaced 114-inch
<br /> 5-322. Grade 40 steel combination,min.1-inch attach EverGuard TPO SXHD Plates o.c.and sealed with a 1.5-inch heat weld. 37.5
<br /> Min.22 ga.,type B, One or more layers,any Prelim. Drill-Tec XHD or SXHD with Drill-Tec 2 3/4 in. 12-inch o.c.within 6-inch wide laps spaced 114-inch
<br /> 5-323. Grade 80 steel combination,min.1.5-inch attach EverGuard TPO Barbed SXHD Plates o.c.and sealed with a 1.5-inch heat weld. 37.5
<br /> Min.22 ga.,type B, One or more layers,any Prelim. Drill-Tec XHD with Drill-Tec 2 3/8 in.Barbed 12-inch o.c.within 5-inch wide laps spaced 115-inch
<br /> 5-324. Grade 80 steel combination,min.1.5-inch attach EverGuard TPO XHD Plates D.c.and sealed with a 1.5-inch heat weld. 37.5
<br /> Min.22 ga.,type B, i
<br /> One or more layers,any Prelim. Drill-Tec SXHD with Drill-Tec 2 3/4 in.Barbed 12-inch o.c.within 6-inch wide laps spaced 138-inch
<br /> 5-325. Grade 80 steel;6 ft combination,min.1-inch attach EverGuard TPO SXHD Plates o.c,and sealed with a 1.5-inch heat weld. 37.5
<br /> span
<br /> Drill-Tec XHD with Drill-Tec 2 in.Double Barbed
<br /> Min.22 ga.,type B, One or more layers,any Prelim. XHD Plates or Drill-Tec 2 3/8 in.Barbed XHD 12-inch o.c.within 6-inch wide laps spaced 54-inch o.c.
<br /> 5-326. Grade 33 steel combination,min.1-inch attach EverGuard TPO Plates;or Drill-Tec SXHD with Drill-Tec 2 3/4 in. and sealed with a 1.5-inch heat weld. 45.0
<br /> Barbed SXHD Plates
<br /> EverGuard TPO Drill-Tec XHD with Drill-Tec 2 in.Double Barbed
<br /> S-327. Min.22 ga.,type B, Min.200 psi,min.2-inch thick Prelim, or EverGuard XHD Plates,Drill-Tec Eyehook AccuSeam Plates 12-inch o.c.within 6-Inch wide laps spaced 54-inch o.c. -45.0
<br /> Grade 33 steel cellular lightweight concrete attach TPO FB Ultra or Drill Tec 2-3/8 in.Barbed XHD Plates and sealed with a 1.5-inch heatjweld.
<br /> i
<br /> NEMO ETC,LLC Evaluation Report 01506.09.05-R31 for FL5293-1130
<br /> Certificate of Authorization#32455 611 Edition(2017)FBC NON-HVH2 EVALUATION Revision 31:08/16/2018
<br /> Prepared by: Robert Nieminen,PE-59166 GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 49 of 99