Laserfiche WebLink
i <br /> O, NEM j etc. <br /> TABLE 21: STEEL OR STRUCTURAL CONCRETI�DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER <br /> SYSTEM TYPE D-1: MECHANICALLY ATTACHED ROOF COVER <br /> Deck-. _ Insulation(Note 14)_ Roof Cover. -MDP <br /> System No. <br /> (Note 1) Type . ''Attach Membrane,. Fasteners Attachment (psf) <br /> Min.22 ga.,type B, One or more layers,any Prelim. Drill-Tec XHD with Drill-Tec 2 in.Double Barbed 12-inch o.c.within 6-inch wide laps spaced 66-inch o.c. <br /> 5-328. Grade 40 steel combination,min.1-inch attach EverGuard TPO XHD Plates and sealed with a 1.5-inch heat weld. 45.0 <br /> Min.22 ga.,type B, One or more layers,any Prelim. Drill-Tec SXHD with Drill-Tec 2 3/4 in.Barbed 12-inch o.c.within 6-inch wide laps spaced 90-inch O.C. <br /> 5-329. Grade 33 steel combination,min.1-inch attach EverGuard TPO SXHD Plates and sealed with a 1.5-inch heat weld. 45.0 <br /> S-330. Min.20 ga.,type B, One or more layers,any Prelim. Drill-Tec XHD with Drill-Tec 2 3/4 in.Barbed 12-inch o.c.within 6-inch wide laps spaced 90-inch o.c. <br /> EverGuard TPO 45.0 <br /> Grade 33 steel combination,min.1-inch attach SXHD Plates and sealed with a 1.5-inch heat weld. <br /> S-331. Min.22 ga.,type B, One or more layers,any Prelim. Drill-Tec XHD with Drill-Tec 2 3/8 in.Barbed 6-inch o.c.within 5-inch wide I,aps spaced 114.5-inch <br /> Grade 80 steel combination,min.1.5-inch attach EverGuard TPO XHD Plates o.c.and sealed with a 1.75-inch heat weld. 45.0 <br /> Min.22 ga.,type B, One or more layers,any Prelim. Drill-Tec SXHD with Drill-Tec 2 3/4 in.Barbed 12-inch o.c.within 6-inch wide laps spaced 114-inch <br /> 5-332. Grade 80 steel combination,min.1-inch attach EverGuard TPO SXHD Plates o.c.and sealed with a 1.5-inchlheat weld. 45.0 <br /> Drill-Tec XHD with Drill-Tec 2-3/8 in.Barbed I <br /> Min.20 ga.,type B, XHD Plates,Drill-Tec Eyehook AccuSeam Plates <br /> One or more layers,any Prelim. 6-inch o.c.within 6-inch wide laps spaced 138-inch o.c. _45.0 <br /> S-333. Grade 80 steel;6 ft EverGuard TPO or Drill-Tec 2 in.Double Barbed XHD Plates or <br /> combination,min.1-inch attach and sealed with a 1.5-inch heat weld.-- <br /> span Drill-Tec XHD or SXHD with Drill-Tec 2 3/4 in. <br /> Barbed SXHD Plates <br /> Drill-Tec XHD with Drill-Tec 2-3/8 in.Barbed <br /> Min.22 ga.,type B, XHD Plates,Drill-Tec Eyehook AccuSeam Plates <br /> S-334. Grade 80 steel;5 ft One or more layers,any Prelim. EverGuard TPO or Drill-Tec 2 in.Double Barbed XHD Plates or 6-inch within 6-inch wide laps spaced 138-inch o.c. <br /> combination min h -45.0 <br /> span , .1-inch attac Drill-Tec XHD or SXHD with Drill-Tec 2 3/4 in. and sealed with a 1.5-inch heat weld. <br /> Barbed SXHD Plates <br /> Drill-Tec XHD with Drill-Tec 2-3/8 in.Barbed <br /> Min.18 ga.,type B, XHD Plates,Drill-Tec Eyehook AccuSeam Plates <br /> S-335. Grade 33 steel;4.5 ft One or more layers,any Prelim. and sealle EverGuard TPO or Drill-Tec 2 in.Double Barbed XHD Plates or 6-inch sealed with a 1.5-inch hea within 6-inch wide le weld.aps spaced 138-inch o.c. <br /> combination,min.1-inch attach -45.0 <br /> span Drill-Tec XHD or SXHD with Drill-Tec 2 3/4 in. l <br /> Barbed SXHD Plates <br /> Min.22 ga.,type B, One or more layers,any Prelim. Drill-Tec XHD with Drill-Tec 2 in.Double Barbed 12-inch o.c.within 6-inch wide laps spaced 54-inch o.c. <br /> 5-336. Grade 40 steel combination,min.1-inch attach EverGuard TPO XHD Plates and sealed with a 1.5-inch heat weld. 52.5 <br /> S-337. Min.22 ga.,type B, One or more layers,any Prelim. EverGuard TPO Drill-Tec XHD with Drill-Tec 2 3/4 in.Barbed 12-inch o.c,within 6-inch wide,laps spaced 66-inch o.c. -52.5 <br /> Grade 40 steel combination,min.1-inch attach SXHD Plates and sealed with a 1.5-inch heat weld. <br /> Drill-Tec XHD with Drill-Tec 2-3/8 in Barbed I <br /> . <br /> Min.22 ga.,type B, One or more layers,any Prelim. 6-inch o.c.within 6-inch wide laps spaced 114-inch o.c. <br /> S-338. Grade 33 steel combination,min.1-inch attach EverGuard TPO XHD Plates,Drill-Tec Eyehook AccuSeam Plates -52.5 <br /> or Drill-Tec 2 in.Double Barbed XHD Plates and sealed with a 1.5-inch heat weld. <br /> Prelim. Drill-Tec#14 or Drill-Tec CD-10 fasteners with <br /> S-339. Structural concrete attach or EverGuard TPO <br /> One or more layers,any Drill-Tec 2 in.Double Barbed XHD Plates,Drill- 6-inch o.c.within 6-inch wide laps spaced 114-inch o.c. -52.5 <br /> combination,min.1.5-inch OB500 Tec 2-3/8 in.Barbed XHD Plates or Drill-Tec and sealed with a 1.5-inch heat weld. <br /> Eyehook AccuSeam Plates <br /> 5-340. Min.22 ga.,type B, One or more layers,any Prelim. Drill-Tec XHD with Drill-Tec 2 3/8 in.Barbed EverGuard TPO XHD Plates or Drill-Tec 2 in.Double Barbed XHD 6-inch o.c.within 5-inch wide laps spaced 115-inch o.c. _52.5 <br /> Plates <br /> Grade 80 steel combination,min.1.5-inch attach and sealed with a 1.5-inch heat weld. <br /> I <br /> NEMO ETC,LLC Evaluation Report 01506.09.05-1131 for FL5293-1130 <br /> Certificate of Authorization#32455 6"Edition(2017)FBC NON-HVHZ EVALUATION I Revision 31:08/16/2018 <br /> Prepared by: Robert Nieminen,PE-59166 GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 50 of 99 <br />