<br /> TABLE 21:STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER
<br /> SYSTEM TYPE D-1: MECHANICALLY ATTACHED ROOF COVER
<br /> Deck. tnsulation{Note 24}' Roof Cover ( Mpp
<br /> System No. (Note 1). Type Attach Membrane Fasteners Attachment. (Psf)
<br /> Min.18 ga.,type B,
<br /> P One or more layers,any Prelim. EverGuard TPO Drill-Tec XHD or SXHD with Drill-Tec 2 3/4 in. 6-inch o.c,within 6-inch wide laps spaced 138-inch o.c. -52.5
<br /> S 341. spans 80 steel'6 ft combination,min.1-inch attach Barbed SXHD Plates and sealed with a 1.5-inch heap weld.
<br /> Min.20 ga.,type B, One or more layers,any Prelim. Drill-Tec XHD or SXHD with Drill-Tec 2 3/4 in. 6-inch o.c.within 6-inch wide laps spaced 138-inch o.c.
<br /> S 342. Grade 80 steel;5.5 ft combination,min.1-inch attach EverGuard TPO Barbed SXHD Plates and sealed with a 1.5-inch heat weld. -52.5
<br /> span
<br /> Min.22 ga.,type B, One or more layers,any Prelim. Drill-Tec XHD or SXHD with Drill Tec 2 3/4 in. 6-inch o.c.within 6-inch wide laps spaced 138-Inch ox,
<br /> 5-343. Grade 80 steel;4.5ft combination,min.1-inch attach EverGuard TPO Barbed SXHD Plates and sealed with a 1.5-inch heat weld. -52.5
<br /> span
<br /> Min.22 ga.,type B, One or more layers,any Prelim. Drill-Tec XHD with Drill-Tec 2 3/8 in.Barbed 6-inch o.c.within 6-inch wide Iaps spaced 54-inch o.c.
<br /> 5-344. Grade 33 steel combination,min.1.5-inch attach EverGuard TPO XHD Plates and sealed with a 1.5-inch heat weld. -60.0
<br /> Min.22 ga.,type B, One or more layers,any Prelim. Drill-Tec XHD with Drill-Tec 2 3/4 in.Barbed 12-inch o.c,within 6-inch wide laps spaced 54-inch o.c.
<br /> 5-345. Grade 40 steel combination,min.1-inch attach EverGuard TPO SXHD Plates and sealed with a 1.5-inch heat weld. 60.0
<br /> Min.22 ga.,type B, One or more layers,any Prelim. Drill-Tec XHD with Drill-Tec 2 3/8 in.Barbed 6-inch o.c.within 6-inch wide laps spaced 90-inch o.c.
<br /> 5-346. Grade 33 steel combination,min.1-inch attach EverGuard TPO XHD Plates and sealed with a 1.5-inch heat weld. 60.0
<br /> Min.22 ga.,type B, One or more layers,any Prelim. Drill-Tec XHD with Drill-Tec 2 in.Double Barbed 6-inch o.c.within 6-inch wide laps spaced 114-inch o.c.
<br /> 5-347. Grade 33 steel combination,min.1-inch attach EverGuard TPO XHD Plates and sealed with a 1.5-inch heat weld. 60.0
<br /> EverGuard TPO
<br /> Min.22 ga.,type B, Min.200 psi,min.2-inch thick Prelim. Drill-Tec XHD with Drill-Tec 2-3/4 in.SXHD 124nch o.c.within 6-Inch wide laps spaced 54-inch o.c.
<br /> 5-348. Grade 33 steel cellular lightweight concrete attach TPO FB Ultra or EverGuard Plates and sealed with a 1.5-inch heat weld. 67.5
<br /> l
<br /> Min.22 ga.,type BV Min.330 psi,min.2-inch thick Drill-Tec XHD with Drill-Tec 2 in.Double Barbed Fastened through to engage steel deck,6-inch o.c.
<br /> S-349. N/A EverGuard TPO within 6-inch wide laps spaced 114-inch o.c.and sealed -67.5
<br /> (0.5%),Grade 33 steel Celcore Cellular Concrete XHD Plates(to engage steel deck) with a 1.5-'Inch heat weld.
<br /> Min.22 ga.,type B, One or more layers,any Prelim. Drill-Tec XHD with Drill-Tec 2 3/4 in.Barbed 6-inch o.c,within 6-inch wide laps spaced 114-inch o.c.
<br /> 5-350. Grade 33 steel combination,min.1-inch attach EverGuard TPO SXHD Plates and sealed with a 1.5-inch heat weld. 67.5
<br /> One or more layers,min.1.5- 5 fasteners
<br /> Min.18 ga.,type B, /plates Drill-Tec XHD Fasteners with Drill-Tec 2 in. 6-inch o.c.within 6-inch wide laps spaced 114-inch o.c.
<br /> 5-351, per 4 x 4 ft inch EnergyGuard Polyiso EverGuard TPO -90.0
<br /> Grade 33 steel Double Barbed XHD Plates and sealed with a 1.5-inch heat weld.
<br /> Insulation,EnergyGuard Ultra board
<br /> EVERGUARD TPO FB'ULTRA: - - - -
<br /> Min.22 ga.,type B, Drill-Tec XHD(steel only)or Drill-Tec#14
<br /> One or more layers,any Prelim. EverGuard TPO 6-inch o.c.within min.6-inch wide laps spaced 114-
<br /> S 352. Grade 33 steel combination,min.1.5-inch attach FB Ultra Fasteners{concrete only)with Drill-Tec 2 3/8 in. inch o.c.and sealed with a 1.625-inch heat weld. 45.0
<br /> structrural concrete Barbed XHD Plates I
<br /> Min.22 ga,type B, Drill-Tec XHD(steel only)or Drill-Tec#14 1
<br /> One or more layers,any Prelim. EverGuard TPO 6-inch o.c.within min.6-inch wide laps spaced 112.5-
<br /> S-353. Grade 33 steel or Fasteners(concrete only)with Drill-Tec 2 3/8 in. I -60.0
<br /> structrural concrete combination,min.1.5-inch attach FB Ultra Barbed XHD Plates inch o.c.and sealed with a 1.625-inch heat weld.
<br /> Min.200 psi,min.3-inch thick Fastened through to engage steel deck,6-inch o.c.
<br /> Min.22 ga.,type BV EverGuard TPO Drill Tec XHD with DHII-Tec 2 in.Double Barbed
<br /> S-354. (0.5%),Grade 33 steel Insulating Elastizell
<br /> Lightweight N/A FB Ultra XHD Plates(to engage steel deck) within 6-inch wide laps spaced 114-inch o.c.and sealed 75.0
<br /> nsulg Concrete with a 1.5-inch heat weld.
<br /> I
<br /> NEMO ETC,LLC Evaluation Report 01506.09.05-R31 for FL5293-1130
<br /> Certificate of Authorization#32455 61h Edition(2017)FBC NON-HVH2 EVALUATION Revision 31:08/16/2018
<br /> Prepared by: Robert Nieminen,PE-59166 GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 I Appendix 1,Page 51 of 99