Laserfiche WebLink
6. . <br /> D <br /> Q <br /> r. <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. FF.E shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> I Lots shall be graded t . cor'' ly with R401.3 of the F.B.C. <br /> 3. Compaction test required if 24"or more of fill-dirt is brought in at any one.place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5. Driveways require a R.O.W. use permit. All 4 sides_ of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6: All setbacks shall be-met. <br /> -7: All property markers shall be uncovered,and marked at time of first inspection. <br /> 8: All A:D.A.requirements shall be met: <br /> 9.. No electric,.plumbing; mechanical, or framing shall.be covered without an inspection and <br /> approval first. <br /> 10-. All Garages all comply with section R302.6 of the F.B-C. (Fire Separation): <br /> 11. Appliances shall not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M303.4 of the F.B.0 <br /> 12. Water-heater-s shall comply with section P607.3 of the F.B.C: <br /> 13. Foundation supports for A/C units shall be raised at least 3" above finislied grade. M1308.1 <br /> 14. Return air in all bedrooms: F.B.C. M1620,4 <br /> 1.5. Smoke detectors are to be installed in accordance with R3111 of.the F.B.C. <br /> 16. A11 glazing requirements are to be in accordance with R308:4-of the F.B.-C.; <br /> 17. All means.of egress are to be in accordance'with R311 of the F.B.C: <br /> 18. "Green gypsum,board" shall riot be used as a backer,in showers or tubs. R702.4.2 F.B.C. <br /> 19: Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will bete 'uired in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C. <br /> 21. All plumbing, mechanical, and electrical shall be separate from unit to unit: This includes all <br /> underground plumbing and electric., <br /> 22. All 2016 N.E.C. Codes will be enforced: <br />