Laserfiche WebLink
23. Tamper- Resistant Receptacles in accordance with 406.11 of the pi N.E:C <br /> 24. In accordance with the Land Development Code,lots shall be sodded before final at_least 10 <br /> feet around the structure. <br /> 25. R403.5.Mof.water pipe insulation. <br /> Insulation for hot water pipe With a"minimum thermal resistance (R-value) of R-3 shall.be applied to the <br /> following: . - <br /> Piping.V. inch (19.1 mm)and larger in nominal diameter. <br /> Piping.serving more than one dwelling unit: <br /> Piping 10 catiad outside the conditioned space, <br /> Piping from the water heater to a distribution manifold: <br /> Piping.located under a floor slab. <br /> Buried in piping. <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25. Blower dloor test shall be provided before C.O: <br /> 26.A copy of the energy cacls shall be with permit at all times <br /> 2Z Copy of Fnal insulation report shall be provided with permit before rnaL <br /> 28. No fence, pool or screen enclosure .is issued with ahis permit <br /> F.F.E.-Finished Floor Elevation <br /> RB.C-.=Florida Building Code 6d Edition <br /> R.O.W.-Right of Way <br /> A.D.A.=Americans with Disabilities Act N.E.C.-National Electric Code(2016) <br />