Laserfiche WebLink
D <br /> {- <br /> r. r <br /> i <br /> i <br /> Single Family Dwelling <br /> Plan Review Comments- <br /> 1. F.F.E: shall be a minimum of 8" above the road elevation and.an engineered site plan. <br /> 2. Lots shall be graded to comply with R401:3:of the F.B.C. <br /> 3: Compaction test required if 24" or more of fill dirt is brought in at-any one.place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5. Driveways require.a R,O:W. use permit. All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6: All setbacks shall be met. <br /> 7: All,property markers shall be uncovered and:marked at time:of first inspection. <br /> 8: All A:D.A.requirements shall be met: <br /> 9. No electric,.plumbing;mechanical, or framing shall be covered without an inspection and <br /> approval first: <br /> 10.. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation): <br /> 11. Appliances shall not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M303.4 of the F.B.0 . <br /> 12. Water heaters shall comply with section P607.3 ofthe F.B.C. <br /> 13. Foundation supports for AX units shall be raised at least 3" above finished grade. M1308:1 <br /> 14. Return air in all bedrooms. F.B.C. M1620:4 <br /> 1.5. Smoke deteetors.are to be installed in accordance with R3111 of.the F.B.C. <br /> 16. All glazing requirements are to be.in accordance with R308.4.of the F.B.C! <br /> .1 T.All means.of egress are to be in accordance with R311 of the F.B.0 <br /> 18. `-`Green gypsum.board" shall riot be Used as a backer in showers or tubs. R702.4:2 F.B.C. . <br /> 10. Combination-type AM breakers are required at all locations requiring an AM.type breaker. <br /> 20. Carbon monoxide alarms will.be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage.' They shall.be installed in accordance with the F.B.C: <br /> 2:1. All plumbing,mechanical; and electrical shall be separate from unit to unit: This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced. <br />