Laserfiche WebLink
FORM R405-2017 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> i <br /> Project Name: R0620223LTE Builder Name: <br /> Street: 7145 Landover Dr Permit Office: City of Zephyrhills <br /> City,State,Zip: Zephyrhills,FL,33540 Permit Number: ( 9& <br /> Owner. Price Jurisdiction: 611600 <br /> Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing Addition 9. Wall Types(704.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.5 352.00 ft2 <br /> b.Concrete Block-Int Insul,Exterior R=15.0 264.00 ft2 <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=13.0 88.00 ft2 <br /> 4. Number of Bedrooms(Bedrms In Addition) 0(0) d.N/A R= ft2 <br /> 5. Is this a worst case? No 10.Ceiling Types (660.0 sqft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 660.00 ft2 <br /> 6. Conditioned floor area above grade(ft) 660 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11.Ducts R ft2 <br /> 7. Windows(116.0 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Garage 6 25 <br /> a. U-Factor. Dbl,U=0.40 116.00 ft2 <br /> SHGC: SHGC=0.25 <br /> b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: a.Central Unit 36.0 SEER:14.00 <br /> b.Central Unit 12.0 SEER:18.00 <br /> c. U-Factor. N/A ft2 <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor. N/A ft2 a.Electric Heat Pump 36.0 HSPF:8.20 <br /> SHGC: b.Electric Heat Pump 12.2 HSPF:10.00 <br /> Area Weighted Average Overhang Depth: 1.333 ft. <br /> Area Weighted Average SHGC: 0.250 14.Hot water systems-None required <br /> a' Cap:N/A <br /> 8. Floor Types (660.0 sqft.) Insulation Area <br /> EF:0.000 <br /> a.Slab-On-Grade Edge Insulation R=0.0 660.00 ft2 b. Conservation features <br /> b.N/A R= ft2 <br /> c.N/A R= ft2 15.Credits CF,Pstat <br /> Glass/Floor Area: 0.176 Total Proposed Modified Loads: 15.08 PASS <br /> Total Baseline Loads: 19.14 <br /> I hereby certify that the plans and specifications covered by '', Review of the plans and keS$E Sp,4?� <br /> this calculation are in compliance with the Florida Energy i specifications covered by this <br /> Code. calculation indicates compliance <br /> with the Florida Energy Code. rrra a <br /> PREPARED BY: Before construction is completed <br /> DATE: 06-16-20 this building will be inspected for <br /> compliance with Section 553.908 * ° <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. , 5�S <br /> With the Florida Energy Code. cOD we <br /> OWNER/ GEN � 1 BUILDING OFFICIAL: <br /> DATE: ��/ -� DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed In accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).(Exception may apply) <br /> 6/16/2020 3:06 PM EnergyGaugeO USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 4 <br />