Laserfiche WebLink
Job: 0620223 <br /> wrightsoft® Project Summary Date: Jun 16,2020 <br /> AMTek-IBuhhh H.ftwayCo pmy AHU I,/ By: AMA <br /> Randy Watson Designs Inc <br /> 13821 US Hwy 98 By Pass,Dade City,FL 33523 Phone:352-623-2077 <br /> Project Information <br /> For: Price <br /> 7145 Landover Dr, Zephyrhills, FL 33540 <br /> Notes: Load calculation was obtained from a digital copy of the CAD drawing. <br /> - Design Information <br /> Weather: Tampa Intl AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 43 OF Outside db 91 OF <br /> Inside db 70 OF Inside db 75 OF <br /> Design TD 27 OF Design TD 16 OF <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 54 gr/lb <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 9233 Btuh Structure 9547 Btuh <br /> Ducts 3762 Btuh Ducts 6521 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh <br /> (none) (none) <br /> Humidification 0 Btuh Blower 11k Btuh <br /> Piping 0 Btuh <br /> Equipment load 12995 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipmenfsensible load 26648 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Average <br /> Fireplaces 0 Structure 3202 Btuh <br /> Ducts 1604 Btuh <br /> Central vent(0 cfm) 0 Btuh <br /> Heating cooling (none) <br /> Area(ftZ 1252 1252 Equipment latent load 4806 Btuh <br /> Volume(ft') 10016 10016 <br /> Air changes/hour 0.34 0.18 Equipment Total Load (Sen+Lat) 31454 Btuh <br /> Equiv.AVF(cfm) 57 30 Req. total capacity at 0.75 SHR 3.0 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make 3 Ton- Existing Make 3 Ton- Existing <br /> Trade Existing Split HP Trade Existing Split HP <br /> Model Existing 3 Ton Cond Existing 3 Ton <br /> AHRI ref Coil Existing 3 Ton <br /> AHRI ref <br /> Efficiency 8.2 HSPF Efficiency 14 SEER <br /> Heatng input Sensible cooling 27000 Btuh <br /> Heating output 36000 Btuh @ 47°F Latent cooling 9000 Btuh <br /> Temperature rise 27 OF Total cooling 36000 Btuh <br /> Actual air flow 1200 cfm Actual air flow 1200 cfm <br /> Air flow factor 0.092 cfm/Btuh Air flow factor 0.075 cfm/Btuh <br /> Static pressure 0 in H2O Static pressure 0 in H2O <br /> Space thermostat Load sensible heat ratio 0.85 <br /> Capacity balance point=0 OF <br /> Backup: Aux. Heat <br /> Input= 10 kW, Output= 34121 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> -'F wrigfttsoft- 2020-Jun-1614:29:10 <br /> .- n�a_ �..,,.m Right-Suite®Universal 2019 19.0.18 RSU20773 Page 1 <br /> ...0620223-Randy Watson-Price-L-E%R0620223.rup Calc=MA 'Front Door faces: E <br />