Laserfiche WebLink
- Project Summary Job, R0620223 <br /> wrightsot Date: Jun 16,2020 <br /> A MiAL-f&d hn Mt wq Q.pany Mini Split By: AMA <br /> Randy Watson Designs Inc <br /> 13821 US Hwy 98 By Pass,Dade City,FL 33523 Phone:352523-2077 <br /> Project • • <br /> For: Price <br /> 7145 Landover Dr, Zephyrhills, FL 33540 <br /> Notes: Load calculation was obtained from a digital copy of the CAD drawing. <br /> Desicin Information <br /> Weather: Tampa Intl AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 43 OF Outside db 91 OF <br /> Inside db 70 OF Inside db 75 OF <br /> Design TD 27 OF Design TD 16 OF <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 54 gr/lb <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 5589 Btuh Structure 4898 Btuh <br /> Ducts 0 Btuh Ducts 0 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh <br /> (none) (none) <br /> Humidification 0 Btuh Blower 3925 Btuh <br /> Piping 0 Btuh <br /> Equipment load 5589 Btuh Use manufacturer's data y <br /> Rate/swingg multiplier 1.00 <br /> Infiltration - Equipmenfsensible load 8823 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Average <br /> Fireplaces 0, Structure 1649 Btuh <br /> Ducts 0 Btuh <br /> Central vent(0 cfm) 0 Btuh <br /> Beatingg cooling (none) <br /> Area(ftz 528 528 Equipment latent load 1649 Btuh <br /> Volume(ft3) 5148 5148 <br /> Air changes/hour 0.45 0.24 Equipment Total Load (Sen+Lat) 10472 Btuh <br /> Equiv.AVF(cfm) 39 20 Req. total capacity at 0.75 SHR 1.0 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make 1 Ton- Mitsubishi or Eqv. Make 1 Ton- Mitsubishi or Eqv. <br /> Trade Mini Split HP Trade Mini Split HP <br /> Model MUZ-HM12 Cond MUZ-HM12 <br /> AHRI ref 202680601 Coil MSZ-HM12 <br /> AHRI ref 202680601 <br /> Efficiency 10 HSPF Efficiency 9.9 EER, 18 SEER <br /> Heating input Sensible cooling 9000 Btuh <br /> Heating output 12200 Btuh @ 47°F Latent cooling 3000 Btuh <br /> Temperature rise 28 OF Total cooling 12000 Btuh <br /> Actual air flow 400 cfm Actual air flow 400 cfm <br /> Air flow factor 0.072 cfm/Btuh Air flow factor 0.082 cfm/Btuh <br /> Static pressure 0 in H2O Static pressure 0 in H2O <br /> Space thermostat Load sensible heat ratio 0.84 <br /> Capacity balance point=23 OF <br /> Backup: Aux. Heat <br /> Input= 5 kW, Output= 17061 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> =igF�tsoit® 2020-Jun-16 14:29:10 <br /> �_.»_.,.•,.-.� Right-Suite®Universal 2019 19.0.18 RSU20773 Page 2 <br /> AC.G� ...0620223-Randy Watson-Price-L-E1R0620223.rup Calc=MJ8 Front Door faces: E <br />