My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-695
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-695
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/6/2022 8:43:55 AM
Creation date
2/24/2022 10:20:32 AM
Metadata
Fields
Template:
Building Department
Company Name
PULTE HOME COMPANY LLC
Building Department - Doc Type
Permit
Permit #
20-695
Building Department - Name
PULTE HOME COMPANY LLC
Address
6403 BRADFORD WOODS DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Manual S Compliance Report Job: R0620223 <br /> - - Wrightsoft® P P Date: Jun 16,2020 <br /> AMAO/Berkshire Nftway 0-paq AHU1 By: AMA <br /> Randy Watson Designs Inc <br /> 13821 US Hwy 98 By Pass,Dade City,FL 33523 Phone:352523-2077 <br /> Project • • <br /> For: Price <br /> 7145 Landover Dr, Zephyrhills, FL 33540 <br /> Cooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.4°F Sensible gain: 26648 Btuh Entering coil DB: 85.7°F <br /> Outdoor design WB: 77.2°F Latent gain: 4806 Btuh Entering coil WB: 66.4°F <br /> Indoor design DB: 75.0°F Total gain: 31454 Btuh <br /> Indoor RH: 50% Estimated airflow: 1200 cfm <br /> Manufacturer's Performance Data at Actual;Design Conditions <br /> Equipment type: SplitASHP <br /> Manufacturer: 3 Ton- Existing Model: Existing 3 Ton+Existing 3 Ton <br /> Actual airflow: 1200 cfm <br /> Sensible capacity: 27000 Btuh 101% of load <br /> Latent capacity: 9000 Btuh 187% of load <br /> Total capacity: 36000 Btuh 114% of load SHR: 75% <br /> Heating Equipment <br /> Design Conditions <br /> Outdoor design DB: 42.9°F Heat loss: 12995 Btuh Entering coil DB: 69.2°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: 3 Ton- Existing Model: Existing 3 Ton+Existing 3 Ton <br /> Actual airflow: 1200 cfm <br /> Output capacity: 36000 Btuh 277% of load Capacity balance: 0 OF <br /> Supplemental heat required: 0 Btuh Economic balance: 0 OF <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 1200 cfm <br /> Output capacity: 10.0 kW 263% of load Temp. rise: 26 OF <br /> Meets all requirements of ACCA Manual S. <br /> - wrightsoft- 2020-Jun-1614:29:10 <br /> ,,Rk.,-,aa,e„ Right-Suite®Universal 2019 19.0.18 RSU20773 Page 1 <br /> '0im ...0620223-Randy Watson-Price-L-E%R0620223.rup Calc=MJ8 Front Door faces: E <br />
The URL can be used to link to this page
Your browser does not support the video tag.