Laserfiche WebLink
Manual S Compliance Report Job: R0620223 <br /> wrightsoft® epor Date: Jun 16,2020 <br /> AMAP1Be&N.Hatlaway rompaq Mini Split By: AMA <br /> Randy Watson Designs Inc <br /> 13821 US Hwy 98 By Pass,Dade City,FL 33523 Phone:352-523-2077 <br /> Project • • <br /> For: Price <br /> 7145 Landover Dr, Zephyrhills, FL 33540 <br /> Cooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.4°F Sensible gain: 8823 Btuh Entering coil DB: 84.2°F <br /> Outdoor design WB: 77.2°F Latent gain: 1649 Btuh Entering coil WB: 65.6°F <br /> Indoor design DB: 75.0°F Total gain: 10472 Btuh <br /> Indoor RH: 50% Estimated airflow: 400 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SpIitASHP <br /> Manufacturer: 1 Ton- Mitsubishi Model: MUZ-HM12+MSZ-HM12 <br /> Actual airflow: 400 cfm <br /> Sensible capacity: 9000 Btuh 102% of load , <br /> Latent capacity: 3000 Btuh 182% of load <br /> Total capacity: 12000 Btuh 115% of load - SHR: 75% <br /> Heating Equipment <br /> Design Conditions <br /> Outdoor design DB: 42.9°F Heat loss: 5589 Btuh Entering coil DB: 70.0°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SpIitASHP <br /> Manufacturer: 1 Ton- Mitsubishi Model: MUZ-HM12+MSZ-HM12 <br /> Actual airflow: 400 cfm <br /> Output capacity: 12200 Btuh 218% of load Capacity balance: 23 OF <br /> Supplemental heat required: 0 Btuh Economic balance: -99 OF <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 400 cfm <br /> Output capacity: 5.0 kW 305% of load Temp. rise: 39 OF <br /> Meets all requirements of ACCA Manual S. <br /> -Fp- wrightsoft® 2020-Jun-16 14:29:10 <br /> Right-Suite®Universal 2019 19.0.18 RSU20773 Page 2 <br /> /�+CA ...0620223-Randy Watson-Price-L-E1R0620223.rup Calc=MJ8 Front Door faces: E <br />