My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-724
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-724
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/6/2022 8:47:31 AM
Creation date
2/24/2022 11:10:50 AM
Metadata
Fields
Template:
Building Department
Company Name
ADVENTIST HEALTH SYSTEM/SUNBELT INC
Building Department - Doc Type
Permit
Permit #
20-724
Building Department - Name
ADVENTIST HEALTH SYSTEM/SUNBELT INC
Address
7050 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Model FC Model W3 <br /> For use with Model G5 Series sprinklers For use with Model G5 Series sprinklers with <br /> without wrench-able cap installed wrench-able cap installed <br /> Fully insert the Model W3 wrench over the cap until it reaches Replace any sprinkler or cover plate which has been painted <br /> the bottom of the cup, or the Model FC wrench over the (other than factory applied). Properly installed Model G5 cover <br /> sprinkler until the wrench engages the body. Do not wrench plates will have an air gap that is required for proper operation, <br /> any other part of the sprinkler/cup assembly.The Model W3 do not seal the gap or paint the cover plates. Model G5 series <br /> and FC wrenches are designed to be turned with a standard sprinklers have holes in the cup that must remain unobstructed. <br /> 1/2'square drive.Tighten the sprinkler into the fitting after Replace any sprinkler which has been damaged. A stock <br /> applying a PTFE based thread sealant to the sprinkler's of spare sprinklers should be maintained to allow quick re- <br /> threads. Recommended installation torque is specified in placement of damaged or operated sprinklers. Failure to <br /> Table J. properly maintain sprinklers may result in inadvertent operation <br /> or non-operation during a fire event. <br /> Installation Torque Table J <br /> Recommended Installation Guarantee <br /> Sprinkler Threads Torque (min.—max.) For the Reliable Automatic Sprinkler Co., Inc.guarantee,terms, <br /> ft.lb N.m and conditions, visit www.reliablesprinkler.com. <br /> 1/2" NPT or IS07-1 R1/2 8-18 11-24 <br /> 3/4" NPT or IS07-1 R3/4 14-20 19-27 Patents <br /> Do not exceed the maximum recommended torque. Exceeding Model G5 series sprinklers may be covered by one or more of <br /> the maximum recommended torque may cause leakage or the following patents: <br /> impairment of the sprinkler.Use care when inserting or removing U.S. Patent 6,554,077, U.S. Patent 7,275,603, U.S. Patent <br /> the wrench from the sprinkler to avoid damage to the sprinkler. 8,776,903, U.S. Patent 9,248,327 <br /> Install the cover plate by hand, pushing and then turning the Ordering Information <br /> cover in the clockwise direction until it is tight against the ceiling. Specify the following when ordering. <br /> For Model G4/G5 OR Gasket and Model G4/G5 SR Gasket cover <br /> plates,the gasket should be attached to the flange of the cover Sprinkler <br /> plate skirt only. Do not glue the gasket in place or allow the ° Model [G5-28] [G5-42] [G5-56] [G5-56 300] <br /> gasket to overlap both the cover plate and the flange of the [G5-80] [G5-80F] <br /> skirt. • Temperature Rating [1650F(740C)] [212°F(100°C)] <br /> • Threads[NPT or ISO 7-1] <br /> Maintenance Cover Plate <br /> Reliable Model G5 series sprinkler should be inspected and the • Model [G4/G5, G4/G5 OR Gasket, G4/G5 SR Gasket] <br /> sprinkler system maintained in accordance with NFPA 25, as • Finish (See Table ]) <br /> well as the requirements of any Authorities Having Jurisdiction. Sprinkler Wrench <br /> Prior to installation, sprinklers should remain in the original • Model W3 <br /> cartons and packaging until used. This will minimize the • Model FC <br /> potential for damage to sprinklers that could cause improper <br /> operation or non-operation. <br /> v <br /> Do not clean sprinklers with soap and water,ammonia liquid or <br /> any other cleaning fluids. Remove dust by gentle vacuuming rn <br /> without touching the sprinkler. <br /> z <br /> a- <br /> Bulletin 034 Page 9 of 9 <br /> January 2020 www.reliablesprinkler.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.