My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-747
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-747
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2022 11:28:41 AM
Creation date
2/24/2022 11:28:40 AM
Metadata
Fields
Template:
Building Department
Company Name
DR HORTON
Building Department - Doc Type
Permit
Permit #
20-747
Building Department - Name
DR HORTON
Address
35660 BURMA REED DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Q <br /> n � <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. FORE.shall be a minimum of 8"above;the road elevation and an engineered site plan. <br /> 2; Lots shall be graded to comply with R401.3.of the F.B.C. <br /> 3. Compaction test required if 247,or more of fill,dirt is brought in at any one place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5. Driveways require a R.O.W.use permit: All 4 sides of driveway thru the sidewalk shall have: <br /> expansion material. <br /> 6: All setbacks shall be met. <br /> 7. All property markers shall be uncovered.and marked at time_of first inspection. <br /> 8. .All A.D.A.-requirements shall,be met: <br /> 9. No electric,.plumbing; mechanical, or framing shall.be covered without an inspection and <br /> approval first: <br /> 10: All.Garages:shall.comply with section M0.16 of the F.B.-C. (Fire Separation). <br /> 1.1.. Appliances shall not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M303-4.of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 of the F.B.C: <br /> 13. Foundation supports for A/C units.shall be raised at least 3" above finished grade. M1308.:1 <br /> A.. Return air,in all bedrooms. F.B.C. M1620.4 <br /> 1.5. Smoke detectors are to be installed_ in accordance with R3-13.1 of the F.B.C. <br /> 16. All glazing requirements are to be in accordance With R308.4 of the F.B.C: <br /> 17. All means of egress are.to be in accordance with R311 of the F.B.C.. <br /> All . <br /> 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702:4.2 F.B.C. <br /> 10. Combination-type AFCI breakers are required at all locations requiring an AFCI.type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.G. <br /> 21. All plumbing,mechanical; and electrical shall be separate from unit to unit. This includes all <br /> underground:plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced: <br />
The URL can be used to link to this page
Your browser does not support the video tag.